Operation at welding end
This section explains the supply stop procedure of power/shield gas after the welding end.
1.
Close the main tap of the shield gas.
2.
Press the GAS CHECK key.
⇒
The LED of the GAS CHECK key lights up, and the shield gas remained in the gas piping is
discharged.
3.
After the shield gas is discharged, press the GAS CHECK key.
⇒
The LED of the GAS CHECK key lights off, to stop gas check.
4.
Set the flow adjustment knob to “SHUT", to adjust the shield gas flow rate to zero.
5.
Turn OFF the power switch of the welding power supply.
⇒
The power LED switch lights off.
6.
Shut off the input power.
●
Operate the disconnect switch to shut off the input power.
SHUT
GAS
Input power supply
Shut off
Cover
OFF
Power switch
Main valve
Flow rate
adjustment knob
GAS CHECK key
Welding power
source
Welding power
source
Summary of Contents for Welbee WB-A350P
Page 2: ......
Page 8: ...TABLE OF CONTENTS vi MEMO ...
Page 28: ...PART NAMES PRODUCT SPECIFICATION AND CONFIGURATION CHAPTER 2 2 12 ...
Page 52: ...CONNECTION OF EXTERNAL EQUIPMENT CONNECTION CHAPTER 4 4 18 ...
Page 108: ...OPERATION OF ANALOG REMOTE CONTROL OPTIONAL WELDING CONDITION CHAPTER 6 6 48 ...
Page 138: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 10 4 10 2 1 Schematic diagram ...
Page 139: ...10 5 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 ...