![Daihen Welbee WB-A350P Owner'S Manual Download Page 62](http://html1.mh-extra.com/html/daihen/welbee-wb-a350p/welbee-wb-a350p_owners-manual_3218080062.webp)
L
IST
OF
W
ELDING
C
ONDITIONS
W
ELDING
C
ONDITION
C
HAPTER
6
6-2
6.1.2
Function
6.1.3
Internal function
Details of internal function ( 6.10
-
Setting Internal Functions)
The functions with circle mark (O) on the Memory row can be stored with the welding conditions.
Function
Initial value
Setting parameter
CRATER-FILL
OFF
OFF/ON/ON (repeat)/Arc Spot
Welding method
AC TIG
AC TIG/AC-DC TIG/DC TIG/AC STICK/DC STICK
AC waveform
Standard
Standard/Soft/Hard
Initial current
OFF
ON/OFF
Lift start
OFF
ON/OFF
Pulse
OFF
ON/OFF
Slope
OFF
ON/OFF
Torch current
adjustment
OFF
ON/OFF
No.
Function Name
Setting range
Initial value
Explanation
Memory
F1
Fine adjustment of starting
current
10 to 200
100 (%)
Fine adjusts the starting current.
—
F2
Cheange in sequence at arc
spot
OFF/ON
OFF
Welding ends even in the arc spot period when the
start switch turns off in the Arc Spot mode.
—
F3
Cheange in sequence at
CRATER-FILL ON (repeat)
OFF/ON
OFF
In CRATER-FILL ON (repeat) mode, welding current
and crater current can be switched over with each
other by tapping the torch switch. Press the start
switch for a long time to stop welding.
○
F4
Auto/Manual mode
0/1/2/3/4
0
Switches the I/O settings of the welding power
source:
0: Manual machine
1: Automatic machine 1
2: Automatic machine 2
3: Almega (OTC’s robots) specification
4: Almega (OTC’s robots) specification (for high
speed communication)
—
F5
Maximum external
command voltage
10.0/12.0/
14.0/15.0
15.0 (V)
Sets the maximum value of voltage supplied when
current/voltage command is externally input.
—
F6
Hazard reducing function
ON/OFF
ON
Sets ON/OFF of the hazard reducing function in the
DC STICK welding mode.
ON: Hazard reducing function is enabled.
OFF: Hazard reducing function is disabled.
—
F7
Pulse width setting
5 to 95
50
Sets the ratio of the pulse width in one cycle during
pulse output
○
F8
Welding result display time
0 to 60
20 (s)
Sets the display time for the current/voltage after
completion of welding.
—
F9
Analog remote control scale
100/200/300/
400
400 (A)
Configures the settings of scale plate of the analog
remote control.
—
F10
Analog remote control
upper limit setting
10 to 380
380 (A)
Sets the upper limit of the current setting range of
the welding current (base current) and the peak
current that can be adjusted by the analog remote
control.
—
F11
Current increase and
decrease by single-clicking
-100 to 100
0 (A)
Increases or decreases the current by single-
clicking of the torch switch. Sets the increase/
decrease value of the current at that time.
○
F12
Current increase and
decrease by double-clicking
-100 to 100
0 (A)
Increases or decreases the current by double-
clicking of the torch switch. Sets the increase/
decrease value of the current at that time.
○
Summary of Contents for Welbee WB-A350P
Page 2: ......
Page 8: ...TABLE OF CONTENTS vi MEMO ...
Page 28: ...PART NAMES PRODUCT SPECIFICATION AND CONFIGURATION CHAPTER 2 2 12 ...
Page 52: ...CONNECTION OF EXTERNAL EQUIPMENT CONNECTION CHAPTER 4 4 18 ...
Page 108: ...OPERATION OF ANALOG REMOTE CONTROL OPTIONAL WELDING CONDITION CHAPTER 6 6 48 ...
Page 138: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 10 4 10 2 1 Schematic diagram ...
Page 139: ...10 5 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 ...