![Daihen Welbee WB-A350P Owner'S Manual Download Page 69](http://html1.mh-extra.com/html/daihen/welbee-wb-a350p/welbee-wb-a350p_owners-manual_3218080069.webp)
6-9
Chapter 6
W
elding Condition
P
REPARING
W
ELDING
C
ONDITIONS
W
ELDING
C
ONDITION
C
HAPTER
6
6.4 Preparing Welding Conditions
This section explains the setting process of basic welding conditions.
6.5 Memory Function of Welding Conditions
This section explains the memory function of welding conditions.
The welding power source is equipped with the function to register the welding conditions and reads
them out for use. The number of welding conditions that are able to be registered are 100 at maximum.
Single welding condition can contain the following information at registration:
• Welding mode selected by the keys on operation panel
• Welding current for each welding sequence ( 6.6.1
-
Setting welding parameter)
• Part of internal function ( 6.1.3
-
Internal function)
Check welding material suitable for the welding condition
(
10.3
-
Materials for Setting Welding Conditions)
↓
Start setting
(
6.6.2
-
Start setting (Touch/High-frequency))
↓
Up-slope setting
(
6.6.4
-
Slope setting)
↓
Setting crater treatment
(
6.6.3
-
Crater setting
-
)
↓
Setting pre-flow (Setting gas discharge time)
(
6.6.1
-
Setting welding parameter)
↓
Initial current setting (Welding current setting)
(
6.6.1
-
Setting welding parameter)
↓
Main welding setting (Welding current pulse setting)
(
6.6.1
-
Setting welding parameter)
↓
Down-slope setting
(
6.6.1
-
Setting welding parameter)
↓
Crater current setting (Welding current setting)
(
6.6.1
-
Setting welding parameter, 6.6.3
-
Crater setting)
↓
Setting post-flow (Setting gas discharge time)
(
6.6.1
-
Setting welding parameter)
↓
Registering the welding conditions set above as necessary
(
6.5
-
Memory Function of Welding Conditions)
• The welding conditions (electronic data) stored by this function are susceptible to
occurrence of static electricity, impact, repair, etc., and there is a possibility that the
stored contents may be changed or lost. BE SURE TO MAKE A COPY FOR IMPORTANT
DATA.
• Please note that OTC will not be liable for any alteration or loss of electronic
information.
Summary of Contents for Welbee WB-A350P
Page 2: ......
Page 8: ...TABLE OF CONTENTS vi MEMO ...
Page 28: ...PART NAMES PRODUCT SPECIFICATION AND CONFIGURATION CHAPTER 2 2 12 ...
Page 52: ...CONNECTION OF EXTERNAL EQUIPMENT CONNECTION CHAPTER 4 4 18 ...
Page 108: ...OPERATION OF ANALOG REMOTE CONTROL OPTIONAL WELDING CONDITION CHAPTER 6 6 48 ...
Page 138: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 10 4 10 2 1 Schematic diagram ...
Page 139: ...10 5 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 ...