M
EMORY
F
UNCTION
OF
W
ELDING
C
ONDITIONS
W
ELDING
C
ONDITION
C
HAPTER
6
6-10
NOTE
• When the analog remote control (option) is connected, the set values of the analog remote
control apply to the welding current (base current) and pulse current values of the main
welding condition even if the registered welding condition is loaded.
T I P S
• Use of the internal function (F44) enables to read out the registered welding condition by the
analog remote control (optional). (
6.10
-
Setting Internal Functions)
6.5.1
Memory registration of welding conditions
This section explains how to register the current welding condition set on the operation panel to the
memory.
1.
Press the SAVE key.
2.
Turn the parameter adjustment knob, and select the JOB No.
3.
Press the ENTER key.
⇒
The system transits to the storage function mode and
the LED of the SAVE key lights up.
⇒
The condition number (registration No.) is displayed
on the right digital meter in a flashing mode, and the
LED of JOB No. lights up.
⇒
On the left digital meter, the setting value of the
welding current registered to the JOB No. if any is
displayed (if there is no registration, "- - -" is
displayed), and the "A" LED lights up.
⇒
When there is no registration data on the selected
JOB No., "- - -" is displayed on the left digital meter.
⇒
When there is any registration data on the selected
JOB No., the setting value of the welding current is
displayed on the left digital meter. At this time, the
LEDs for the keys of crater or wire material also light
up.
⇒
The LED of ENTER key lights up.
⇒
Pressing the DISPLAY CHANGE key enables to
check the value of welding parameter registered in
the JOB No. to overwrite. The setting values are
displayed on the right/left digital meters in a
flashing mode.
⇒
To change the JOB No. to register, press the SAVE
key. The display returns to the status described in
step 1.
⇒
To cancel the memory registration, press the LOAD
key. The storage function mode is terminated.
DC NO-LOAD VOLTAGE
A
sec.
Hz
V/
mm
%
JOB No.
Φ
WARNING
A
sec.
Hz
V/
mm
%
JOB No.
Φ
DC NO-LOAD VOLTAGE
WARNING
ENTER
㧔
3 sec.
㧕
ENTER
㧔
3 sec.
㧕
Summary of Contents for Welbee WB-A350P
Page 2: ......
Page 8: ...TABLE OF CONTENTS vi MEMO ...
Page 28: ...PART NAMES PRODUCT SPECIFICATION AND CONFIGURATION CHAPTER 2 2 12 ...
Page 52: ...CONNECTION OF EXTERNAL EQUIPMENT CONNECTION CHAPTER 4 4 18 ...
Page 108: ...OPERATION OF ANALOG REMOTE CONTROL OPTIONAL WELDING CONDITION CHAPTER 6 6 48 ...
Page 138: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 10 4 10 2 1 Schematic diagram ...
Page 139: ...10 5 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 ...