![Daihen Welbee WB-A350P Owner'S Manual Download Page 63](http://html1.mh-extra.com/html/daihen/welbee-wb-a350p/welbee-wb-a350p_owners-manual_3218080063.webp)
6-3
Chapter 6
W
elding Condition
L
IST
OF
W
ELDING
C
ONDITIONS
W
ELDING
C
ONDITION
C
HAPTER
6
F13
Switchover of current
adjustment operation at
pulse ON
1 to 2
1
You can switch operation as follows when Pulse is
set ON and the current adjustment function by the
torch switch is enabled.
1: Changes pulse current only without changing
base current by click operation.
2: Changes both pulse current and base current at
the same current value (set by F11 and F12) by
click operation.
—
F14
AC ratio
10 to 90
70 (%)
Sets the AC ratio in AC-DC TIG mode.
○
F15
Switchover of cleaning
width display
OFF/ON
OFF
Displays the cleaning width setting in AC TIG mode
and AC-DC TIG mode as EP ratio.
—
F16
Adjustment of pulse
waveform
0/1/2
0
Adjusts the shape of the pulse waveform when the
pulse is set to "ON".
0: Normal pulse
1: Soft pulse
2: Output stable pulse
—
F17
Switchover of memory
condition interlocking
function
OFF/ON
OFF
When connected with the filler control device,
welding conditions memory function of the welding
power source and the wire feed condition memory
function of the filer control device are interlocked
and the memory condition number is sheared.
—
F18
No function
OFF (fixed)
OFF
No functions are provided.
—
F19
Alarm setting switching
OFF/ON
OFF
Sets the output status when an error of the alarm
level is detected:
OFF: Ineffective
ON: Stops the output
—
F20
Low input voltage
detection level
260 to 380
320 (V)
Adjusts the low primary input voltage detection
level.
—
F21
Maximum cooling fan
operation
OFF/ON
OFF
Sets the operation mode of cooling fan:
OFF: Economical operation
ON: Rotates the fan at maximum speed at all time
—
F22
Operation sound switching
OFF/ON
ON
Sets the operation sound when any key is pressed
on the operation panel:
OFF: Turns off the sound
ON: Turns on the sound
—
F23
Sleep mode
switching time
0 to 10
0
Sets the time until the welding power source enters
into sleep mode:
0: OFF
1 to 10: 1 min to 10 min
—
F24
No function
OFF (fixed)
OFF
No functions are provided.
—
F25
External output 1 setting
0 to 4
0
Sets the functions of output terminal of the
programmable I/O.
—
F26
External output 2 setting
F27
External output 3 setting
F28
External output 4 setting
F29
External input 1 setting
0 to 4
0
Sets the functions of input terminal of the
programmable I/O.
—
F30
External input 2 setting
F31
External input 3 setting
F32
External input 4 setting
F33
TIG interval function
OFF/ON
OFF
Suppresses heat input to the work by repeating ON/
OFF of arc during output.
—
F34
TIG interval function Arc ON
time
0.05 to 9.99
0.50
Sets the arc ON time when TIG interval function is
set to "ON".
—
F35
TIG interval function Arc OFF
time
0.05 to 9.99
0.50
Sets the arc ON time when TIG interval function is
set to "OFF".
—
F36
STICK welding torch switch
function
OFF/ON
OFF
You can operate ON/OFF of output in AC STICK
welding mode or DC STICK welding mode by the
ON/OFF operation of the torch switch.
—
No.
Function Name
Setting range
Initial value
Explanation
Memory
Summary of Contents for Welbee WB-A350P
Page 2: ......
Page 8: ...TABLE OF CONTENTS vi MEMO ...
Page 28: ...PART NAMES PRODUCT SPECIFICATION AND CONFIGURATION CHAPTER 2 2 12 ...
Page 52: ...CONNECTION OF EXTERNAL EQUIPMENT CONNECTION CHAPTER 4 4 18 ...
Page 108: ...OPERATION OF ANALOG REMOTE CONTROL OPTIONAL WELDING CONDITION CHAPTER 6 6 48 ...
Page 138: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 10 4 10 2 1 Schematic diagram ...
Page 139: ...10 5 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 ...