6-45
Chapter 6
W
elding Condition
S
ETTING
I
NTERNAL
F
UNCTIONS
W
ELDING
C
ONDITION
C
HAPTER
6
6.10.2.37 F49: Setting of current value (initial current)
The current value of the initial current can be set in percentage based on the current value of the welding
condition.
• Setting range of current value (initial current): 10 % to 300 %
6.10.2.38 F50: Setting of current value (crater current)
The current value of the crater current can be set in percentage based on the current value of the welding
condition.
• Setting range of current value (crater current): 10 % to 300 %
6.10.2.39 F52: Data type of data log function
This function enables to select data to save when using the data log function.
The patterns of data which can be saved are as shown in the below table.
For data log function; ( 7.3
-
Data Backup (Utilization of data)).
6.10.2.40 F53: Sampling speed of data log function
Selects the data sampling interval in using data log function.
The relationship between the setting value and the data sampling is as follows:
For data log function; ( 7.3
-
Data Backup (Utilization of data)).
6.10.2.41 F55 to F59: Reserved
Used in connection with the automatic machines of other manufacturers.
6.10.2.42
F60: Electrode formation function
In the AC TIG mode and AC-DC TIG mode, rounds the electrode at the arc start to form the optimum
electrode shape. Arc is stabilized by rounding the electrode.
This function automatically turns off when welding starts.
When the electrode is replaced, it is necessary to enable this function again.
• When using this function, select the electrode diameter from 063 (
Ʒ
1.6), 094 (
Ʒ
2.4), 126 (
Ʒ
3.2), 157 (
Ʒ
4.0),
189 (
Ʒ
4.8), 220 (
Ʒ
5.6) and 252 (
Ʒ
6.4).
• [OFF]: This function is disabled.
Setting
Welding current
Welding current
Welding voltage
(Command value)
(Detected value)
(Detected value)
0
-
-
-
1
Storable
Storable
Storable
Setting
Sampling interval
1
10 ms
2
100 ms
3
1 s
Summary of Contents for Welbee WB-A350P
Page 2: ......
Page 8: ...TABLE OF CONTENTS vi MEMO ...
Page 28: ...PART NAMES PRODUCT SPECIFICATION AND CONFIGURATION CHAPTER 2 2 12 ...
Page 52: ...CONNECTION OF EXTERNAL EQUIPMENT CONNECTION CHAPTER 4 4 18 ...
Page 108: ...OPERATION OF ANALOG REMOTE CONTROL OPTIONAL WELDING CONDITION CHAPTER 6 6 48 ...
Page 138: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 10 4 10 2 1 Schematic diagram ...
Page 139: ...10 5 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 ...