![Daihen Welbee WB-A350P Owner'S Manual Download Page 112](http://html1.mh-extra.com/html/daihen/welbee-wb-a350p/welbee-wb-a350p_owners-manual_3218080112.webp)
W
ELDING
R
ESULT
C
ONTROL
F
UNCTION
A
DMINISTRATOR
F
UNCTIONS
C
HAPTER
7
7-4
7.2 Welding Result Control Function
This section explains about the welding result control function. The function enables the management of
the items below.
Details of control contents ( 7.2.2
-
Details of welding control items)
7.2.1
Setting welding result control function
This section explains how to set the welding result control function.
1.
Press and hold the WELD MONITOR key for one second or more.
Welding control
parameter
Monitor
No.
Initial
value
Setting range
Explanation
Number of welding
point
P10
0
-
Cumulative number of welding points (number of times)
P11
0
0 to 999
Target value of welding points (number of times)
P12
0
0 to 5
Operation at the time when the target value of welding points
is achieved
Total welding time
P20
0
-
Cumulative total welding time (minute)
P21
0
0 to 999
Target total welding time (minute)
P22
0
0 to 5
Operation at the time when the target total welding time is
achieved
Welding monitor
P30
0
-
Max. fluctuation value of average range monitor (A or V)
P31
100
0 to 100
Current tolerance (+) (%)
P32
100
0 to 100
Current tolerance (-) (%)
P33
100
1 to 100
Welding voltage upper limit value setting (V) (*1)
P34
0
0 to 99
Welding voltage lower limit value setting (V) (*1)
P35
0
0 to 100
WARNING judgment time (second)
P36
0
0 to 2
Operation at the time of WARNING detection
Total operation time
control
P40
0.0
-
Cumulative total operation time (hour) (*2)
P41
0.0
-
Cumulative total welding time (hour) (*2)
P42
oFF
oFF/cLr
Clear of control data value (*3)
*1: Upper limit value is controlled not to become under the lower limit value.
*2: Any value smaller than 100 is displayed up to the first digit below the decimal point.
*3: The values in P10, P20, P40 and P41 will be reset by setting P32 to "cLr" to exit the welding control mode.
⇒
The LED of WELD MONITOR key lights up.
⇒
The monitor No. is displayed on the left digital
meter.
⇒
The data value specified for the monitor No. is
displayed on the right digital meter.
A
sec.
Hz
JOB No.
V/
mm
%
Φ
DC NO-LOAD VOLTAGE
WARNING
WELD
MONITOR
Summary of Contents for Welbee WB-A350P
Page 2: ......
Page 8: ...TABLE OF CONTENTS vi MEMO ...
Page 28: ...PART NAMES PRODUCT SPECIFICATION AND CONFIGURATION CHAPTER 2 2 12 ...
Page 52: ...CONNECTION OF EXTERNAL EQUIPMENT CONNECTION CHAPTER 4 4 18 ...
Page 108: ...OPERATION OF ANALOG REMOTE CONTROL OPTIONAL WELDING CONDITION CHAPTER 6 6 48 ...
Page 138: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 10 4 10 2 1 Schematic diagram ...
Page 139: ...10 5 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 ...