![Daihen Welbee WB-A350P Owner'S Manual Download Page 97](http://html1.mh-extra.com/html/daihen/welbee-wb-a350p/welbee-wb-a350p_owners-manual_3218080097.webp)
6-37
Chapter 6
W
elding Condition
S
ETTING
I
NTERNAL
F
UNCTIONS
W
ELDING
C
ONDITION
C
HAPTER
6
6.10.2.22 F23: Sleep mode switching time
When the welding power source is not operated for a fixed period of time, it can be turned into the sleep
mode.
• [0]: disables the function.
• [1] to [10]: enables the function.
Set the transition time to the sleep mode in the range of 1 to 10. During the sleep mode, power
consumption is reduced.
6.10.2.23 F25 to F28: External output terminal setting
Set the function of external output terminals.
• F25: Sets the function of OUT-EXT1 (3-4) on the external connection terminal block TM4.
• F26: Sets the function of OUT-EXT2 (5-6) on the external connection terminal block TM4.
• F27: Sets the function of OUT-EXT3 (7-8) on the external connection terminal block TM4.
• F28: Sets the function of OUT-EXT1 (9-10) on the external connection terminal block TM4.
Details of external connection terminal blocks ( 4.6.1
-
Connection with external equipment)
The functions set to F25 to F28 are as shown on the table below.
– In the sleep mode, the dot at the first digit on the
left/right digital meters flashes. All the other
displays on the operation panel are turned OFF.
– Any operation during the sleep mode restores the
condition to the previous state.
Setting
Function name
Contents
0
—
No function is allocated.
1
Pulse synchronous
output
When Pulse is set "ON" the circuit between the terminals is closed during the pulse period.
2
Welding monitor alarm
A short-circuit occurs between terminals when a welding monitor alarm (
7.2.2.3
Welding monitor) has occurred.
3
EN synchronous output
In AC TIG mode, the terminals are closed during the EN period (negative electrode).
4
AC synchronous output
In AC-DC TIG mode, the terminals are closed during the AC period.
A
sec.
Hz
JOB No.
V/
mm
%
Φ
DC NO-LOAD VOLTAGE
WARNING
Summary of Contents for Welbee WB-A350P
Page 2: ......
Page 8: ...TABLE OF CONTENTS vi MEMO ...
Page 28: ...PART NAMES PRODUCT SPECIFICATION AND CONFIGURATION CHAPTER 2 2 12 ...
Page 52: ...CONNECTION OF EXTERNAL EQUIPMENT CONNECTION CHAPTER 4 4 18 ...
Page 108: ...OPERATION OF ANALOG REMOTE CONTROL OPTIONAL WELDING CONDITION CHAPTER 6 6 48 ...
Page 138: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 10 4 10 2 1 Schematic diagram ...
Page 139: ...10 5 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 ...