![Daihen Welbee WB-A350P Owner'S Manual Download Page 130](http://html1.mh-extra.com/html/daihen/welbee-wb-a350p/welbee-wb-a350p_owners-manual_3218080130.webp)
I
NSULATION
R
ESISTANCE
M
EASUREMENT
AND
W
ITHSTAND
V
OLTAGE
T
EST
M
AINTENANCE
AND
I
NSPECTION
C
HAPTER
8
8-6
8.5 Insulation Resistance Measurement and Withstand
Voltage Test
If insulation resistance measurement and withstand voltage test is necessary, please contact your dealer.
• When measuring insulation resistance and testing withstand voltage, follow the steps below.
Refer to the schematic diagram, parts layout, and parts list for maintenance.
– Disconnect the input power cable and grounding cable from the disconnect switch and short-circuit
the input terminal.
– Short-circuit the positive (+) and the negative ( - ) sides of the output terminal.
– Unground all the case grounding cables (line No.80, total of 6 positions) and insulate them with
insulation tape.
– For DR1, 2, 5, 6, 7 and 8, short-circuit the AC side and positive (+) output side and the AC side and
negative ( - ) output side, respectively.
– Short-circuit between TR1 (C1) and (E1C2), TR1 (E1C2) and (E2), TR3 (C1) and (E1C2), and TR4 (E2)
and (E1C2).
– Short-circuit between TR5 (C1) and (E1C2), and TR6 (E1C2) and (E2).
– Apply NF.
– After finishing insulation resistance measurement, return the above to the original state.
• The customer MUST NOT perform the withstand voltage test. If withstand voltage test
is necessary, ensure to contact your dealer.
• Insulation resistance measurement should be conducted by qualified persons or
persons familiar with the welding machine. Also, fence and other neccessary measures
should be taken around the welding machine to prevent other people from getting in
the nearby area.
• Conducting insulation resistance measurement by customer may result in injury or
equipment failure. For insulation resistance measurement, be sure to ask your dealer.
• After finishing insulation resistance measurement, it is necessary to remove the
shortcircuit cables and return the welding power source to the original state.
If the power is turned on without returning it to the original state, the welding power
source will burn out.
Summary of Contents for Welbee WB-A350P
Page 2: ......
Page 8: ...TABLE OF CONTENTS vi MEMO ...
Page 28: ...PART NAMES PRODUCT SPECIFICATION AND CONFIGURATION CHAPTER 2 2 12 ...
Page 52: ...CONNECTION OF EXTERNAL EQUIPMENT CONNECTION CHAPTER 4 4 18 ...
Page 108: ...OPERATION OF ANALOG REMOTE CONTROL OPTIONAL WELDING CONDITION CHAPTER 6 6 48 ...
Page 138: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 10 4 10 2 1 Schematic diagram ...
Page 139: ...10 5 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 ...