Chapter 6 Welding Condition
This chapter explains the functions on the operation panel as well as how to set the welding conditions.
6.1 List of Welding Conditions
This section explains the parameters/functions settable in the welding power source.
6.1.1
Parameter (Welding parameter)
Parameter
Set Range
Initial Value
Descriptions
Pre-flow time
0 to 99 sec
0.3 sec
Set the gas discharge time before welding starts.
Displays the value in the unit of 0.1 sec in case of
less than 10 sec.
Displays the value in the unit of 1 sec in case of 10
sec to 99 sec.
Current
Pulse current
1.0 to 380 A
150 A
Pulse current: sets the pulse peak current when
Pulse is ON.
Base current: sets the pulse base current when
Pulse is ON.
Welding current: sets the current value during
welding.
Displays the value in the unit of 0.1 A in case of less
than 10 A.
Displays the value in the unit of 1 A in case of 10 A
to 350 A.
Welding current
(base current)
1.0 to 380 A
150 A
STICK welding:
10 to 380 A
150 A
Sets the current value in the STICK welding mode.
Initial current
1.0 to 380 A
150 A
Sets the current value soon after welding starts.
Crater current
1.0 to 380 A
150 A
Sets the current value soon after welding ends.
Post-flow time
0 to 99 sec
7.0 sec
Set the gas discharge time after the welding ends.
Displays the value in the unit of 0.1 sec in case of
less than 10 sec.
Displays the value in the unit of 1 sec in case of 10
sec to 99 sec.
Arc spot time
0.1 to 10 sec
3.0 sec
Set the welding time at Arc Spot.
Up-slope time
0 to 10 sec
1.0 sec
Sets the slope time from the initial current to the
welding current.
Down-slope time
0 to 10 sec
1.0 sec
Sets the slope time from the welding current to the
crater current.
Welding condition memory No
1 to 100
1
Registers welding conditions. (Capable to register
up to 100.)
Pulse frequency
0.1 to 999 Hz
2.0 Hz
Sets the pulse frequency when Pulse is ON.
Displays the value in the unit of 0.1 Hz in case of
less than 10 Hz.
Displays the value in the unit of 1 Hz in case of 10
Hz to 500 Hz.
Displays the value in the unit of 10 Hz in case of
500 Hz to 700 Hz.
Displays the value in the unit of 20 Hz in case of
700 Hz to 999 Hz.
AC frequency
30 to 500 Hz
70 Hz
Sets the AC frequency in AC TIG mode.
Cleaning width
-20 to 20
0
Sets the strength of cleaning in AC TIG mode.
AC-DC switchover frequency
0.1 to 50 Hz
1 Hz
Sets the AC-DC switchover frequency in AC-DC TIG
mode.
Summary of Contents for Welbee WB-A350P
Page 2: ......
Page 8: ...TABLE OF CONTENTS vi MEMO ...
Page 28: ...PART NAMES PRODUCT SPECIFICATION AND CONFIGURATION CHAPTER 2 2 12 ...
Page 52: ...CONNECTION OF EXTERNAL EQUIPMENT CONNECTION CHAPTER 4 4 18 ...
Page 108: ...OPERATION OF ANALOG REMOTE CONTROL OPTIONAL WELDING CONDITION CHAPTER 6 6 48 ...
Page 138: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 10 4 10 2 1 Schematic diagram ...
Page 139: ...10 5 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 ...