![Daihen Welbee WB-A350P Owner'S Manual Download Page 85](http://html1.mh-extra.com/html/daihen/welbee-wb-a350p/welbee-wb-a350p_owners-manual_3218080085.webp)
6-25
Chapter 6
W
elding Condition
W
ELDING
S
ETTING
G
UIDE
W
ELDING
C
ONDITION
C
HAPTER
6
6.9 Welding Setting Guide
The Welding Setting Guide is a function in which the welding machine automatically determines
appropriate welding conditions such as (Welding current, Initial current (when initial current is
selected), Crater current (when CRATER-FILL ON is selected), Pre-flow time and Post-flow time, and
Up-slope time and Down-slope time) by selecting the electrode diameter, the base metal material, the
weld joint shape, and the base metal plate thickness.
NOTE
• In the Welding Setting Guide, you cannot select the pulse welding of mild steel.
• When the analog remote control is connected, the Welding Setting Guide cannot be used.
6.9.1
Settings of Welding Setting Guide
This section explains how to set the Welding Setting Guide.
1.
Press and hold the WELDING SETTING GUIDE key for one second or more.
2.
Using the parameter adjustment knob and the PARAMETER SELECT key, select an intended setting
item No.
3.
Change the set value by using the parameter adjustment knob and the PARAMETER SELECT key.
⇒
The LED of the WELDING SETTING GUIDE key
turn on in green.
⇒
The setting item No. is displayed on the left digital
meter.
⇒
The set value set to the setting item No. is displayed
on the right digital meter.
●
Pressing the PARAMETER SELECT key makes the
left digital meter lit so that you can change the
setting item No.
●
Change the setting item No. by turning the
parameter adjustment knob. (Example: "S1"
→
"S2"
→
"S3"
→
"S4")
S1: Electrode diameter, S2: Material, S3: Joint, S4:
Plate thickness
( 6.9.2
-
Details of Welding Setting Guide)
●
Pressing the PARAMETER SELECT key makes the
right digital meter lit so that you can change the set
value.
●
Turning the parameter adjusting knob allows you to
change the set value of the set setting item No.
A
sec.
Hz
V/
mm
%
JOB No.
Φ
DC NO-LOAD VOLTAGE
WARNING
SYNERG.
A
sec.
Hz
V/
mm
%
JOB No.
Φ
DC NO-LOAD VOLTAGE
WARNING
+
A
sec.
Hz
JOB No.
V/
mm
%
Φ
DC NO-LOAD VOLTAGE
WARNING
+
Summary of Contents for Welbee WB-A350P
Page 2: ......
Page 8: ...TABLE OF CONTENTS vi MEMO ...
Page 28: ...PART NAMES PRODUCT SPECIFICATION AND CONFIGURATION CHAPTER 2 2 12 ...
Page 52: ...CONNECTION OF EXTERNAL EQUIPMENT CONNECTION CHAPTER 4 4 18 ...
Page 108: ...OPERATION OF ANALOG REMOTE CONTROL OPTIONAL WELDING CONDITION CHAPTER 6 6 48 ...
Page 138: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 10 4 10 2 1 Schematic diagram ...
Page 139: ...10 5 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 ...