Modular L3 Ethernet Switch User’s Guide
16
DES-6309 GBIC Module
Figure 3- 8. Two-port GBIC Module
Two-port, front-panel module
Connects to GBIC devices at full duplex
GBIC Ethernet ports
Fully compliant with IEEE 802.3z
Supports full-duplex operation only
IEEE 802.3x-compliant Flow Control support
Power Supply Modules
Dual power modules design with current sharing design
Full redundant feature design to ensure continuous operation
If one power module failed, the other will take over all current supply
automatically.
Hot-swappable/Hot-pluggable capability
Power management functions
Input: 90 ~ 264 VAC, 47 ~ 63Hz
Output: 3.3V: 80A Max
12V: 2A Max
Led Indicators
The LED indicators of the Switch include CPU Status and Power OK. The following shows the
LED indicators for the Switch along with an explanation of each indicator.
Figure 3- 9. CPU Front Panel LED Indicators
CPU Status
– This center indicator on the front panel displays the current status
of the switch. The LED will blink while the Power-On Self-Test (POST) is
running during startup. It will light a steady green after the POST test to indicate
the switch is powered on and operating properly. It will light amber when an error
occurs during startup and the switch is therefore not functioning.