Procedure
1. Remove the blade from the cabinet.
2. Remove the T15 Torx screws that attach the shroud to the blade and remove the shroud.
3. Remove the T10 Torx screws that attach the air diffuser bracket to the blade and remove the bracket.
4. Disconnect the power cable connectors (press the release tab and pull cable straight out) and remove the
power cable assembly.
5. Locate the defective voltage module.
6. If removing a HIVOC, remove the two IP15 Torx+ screws that attach the voltage module to the daughter card.
7. Remove the voltage module.
●
If removing an Aries VRM, or CPU VRM, grab the corners of the voltage module and carefully wiggle it
side to side to disconnect it from the VRM connector.
Figure 125. VRM Removal
●
For all other voltage modules, grasp the edges of the voltage module and pull out to disconnect it from
the VRM connector.
8. Place the voltage module on an ESD-safe surface.
5.6.2
Install a Voltage Module (VRM, VIVOC, and HIVOC)
Prerequisites
Tools Required:
Adjustable torque driver, 5–40 in-lbs
Compute and IO Blade Procedures
138