Part Number
Description
Procedure
100797100
TRANSDUCER, PRESSURE/
TEMPERATURE 100PSIG
Remove a Redesigned Water
Pressure Transducer
on page
84
Install an Original Water
Pressure and Temperature
Transducer
on page 87
100950700
CABLE ASSY, WATER CONTROL
PCA TO TEMP RTD
Install a Return or Supply
Temperature Sensor
on page 89
Table 5. XC Series-LC Prconditioner
Part Number
Description
Procedure
100673900
SENSOR ASSY, LIQUID SENSE
(INC. 100208502 WATER 4WIRE
5VDC SENSOR)
on page 30
100681001
ACTUATOR ASSY, CONTROL
ARB24-SR W/PLUG SPRING RTN
Install a Non-Spring Returned
Preconditioner Water Valve
Actuator
on page 107
100797100
TRANSDUCER, PRESSURE/
TEMPERATURE 100PSIG
Install an Original Preconditioner
Water Pressure and Temperature
Transducer
on page 114
100513700
SENSOR, HUMIDITY/TEMP
Install a Preconditioner Temperature
and Humidity Sensor
on page 124
100692700
COIL CONTROL ASSY (ON
SYSTEMS SHIPPED PRIOR TO
01/2014)
Install a Preconditioner Coil Control
Board
on page 127
100692701
COIL CONTROL ASSY (SYSTEMS
SHIPPED AFTER 12/2013)
Install a Preconditioner Coil Control
Board
on page 127
Table 6. XC Series-LC Prconditioner Redesigned Components
Part Number
Description
Procedure
100681001
ACTUATOR ASSY, CONTROL
ARB24-SR W/PLUG SPRING RTN
Install a Spring Returned
Preconditioner Water Valve
Actuator
on page 111
100950500
TRANSDUCER, PRESSURE
100PSIG
Install a Redesigned Preconditioner
Water Pressure Transducer
on page
116
100950600
CABLE ASSY, WATER CONTROL
PCA TO PRESSURE SENSOR
Install a Redesigned Preconditioner
Water Pressure Transducer
on page
116
About the XC30-LC and XC40-LC Repair Procedures