7
3
Electrical system
a check of the electrical system to verify that
control desk motor, limit switches and control
panel operate properly must be carried out by
skilled electricians
10 CHAPTER 10 - TROUBLESHOOTING
A list of possible troubles and solutions is given below
T
ROUBLE
:
P
OSSIBLE
C
AUSE
:
S
OLUTION
:
The lift does not work
The main switch is not turned
on
Turn the switch on
There is no power
Check Power on to restore if
necessary
The electrical wires are
disconnected
Replace
Fuses are blown
Replace
Printed circuit board does not
operate properly
Replace the printed circuit
board
The lift does not raise
The motor direction of rotation
is not correct.
Interchange the two phases on
the main switch
The oil in the hydraulic unit is
not sufficient.
Add some hydraulic oil
The UP button is faulty.
Check UP button and
connection for proper
operation. Replace, if needed
The lowering valve does not
close.
Check and clean, if dirty, or
replace, if faulty
The suction pump filter is
dirty.
Check and clean if needed.
The pump is faulty
Check the pump and replace, if
needed.
The lifting capacity is not
sufficient
Oil leakages in hydraulic
circuit
Check the circuit for any
leakage
Exceeding oil into hydraulic
circuit
Push lowering button and
discharging button
simultaneously
The lift does not lower when
the DOWN button is pressed (
without load)
The lowering solenoid valve
does not work properly
Verify if it is powered and
check magneto for damage
(replace if disconnected or
blown).
The lift does not lower when
the DOWN button is pressed
Locking solenoid valve is
jammed
Verify if it is powered and
check magneto for damage
(replace if disconnected or
blown)
The DOWN button is faulty
Replace the DOWN button
Printed circuit board does not
operate properly
Replace the printed circuit
board
Summary of Contents for ERCO 500
Page 14: ...14 Figura 4 LAYOUT PSS MONOFORBICE ESTENSIONE...
Page 15: ...15 Figura 4a LAYOUT PSS MONOFORBICE CON FLAP...
Page 16: ...16 Figura 4b LAYOUT PSS MONOFORBICE ESTENSIONE CON OPERA CIVILE...
Page 17: ...17 Figura 4c LAYOUT PSS MONOFORBICE CON FLAP CON OPERA CIVILE...
Page 21: ...21 Figura 7 SCHEMA ELETTRICO...
Page 29: ...29 Figura 16 COLLEGAMENTO TUBI IDRAULICI A B F...
Page 51: ...51 Figura 4 LAYOUT PSS MONOFORBICE WITH ESTENSION...
Page 52: ...52 Figura 4a LAYOUT PSS MONOFORBICE WITH FLAP...
Page 53: ...53 Figura 4b LAYOUT PSS MONOFORBICE ESTENSION WITH FRAME...
Page 54: ...54 Figura 4c LAYOUT PSS MONOFORBICE FLAP WITH FRAME...
Page 58: ...58 Figure 7 ELECTRICAL DIAGRAM...
Page 66: ...66 Figure 16 HIDRAULIC HOSE CONECTION A B F...
Page 87: ...Figura 4 PLAN D ENSEMBLE F...
Page 88: ...Figura 4a PLAN D ENSEMBLE F...
Page 89: ...Figura 4b PLAN D ENSEMBLE F...
Page 90: ...Figura 4c PLAN D ENSEMBLE F...
Page 94: ...F Figura 7 SCHEMA ELECTRIQUE...
Page 102: ...F Figure 16 RACCORDEMENT DES TUYAUX HYDRAULIQUES A B F...
Page 124: ...124 Bild 4 LAYOUT...
Page 125: ...125 Bild 4a LAYOUT...
Page 126: ...126 Bild 4b LAYOUT...
Page 127: ...127 Bild 4c LAYOUT...
Page 131: ...131 Bild 7 ELEKTROSCHALTPLAN...
Page 139: ...139 Bild 16 ANSCHLIESSEN DER HYDRAULIKLEITUNGEN A B F...
Page 161: ...Figura 4a DISE O DESARROLLADO...
Page 162: ...Figura 4b DISE O DESARROLLADO...
Page 163: ...Figura 4c DISE O DESARROLLADO...
Page 167: ...Figura 7 ESQUEMA EL CTRICO...
Page 175: ...Figura 16 CONEXI N DE LOS TUBOS HIDR ULICOS A B F...