Authen ca on
- Enables the authen ca on of connec ons. Default se ng is No.
Protec on
- Enables AES encryp on and payload integrity protec on to prevent tampering with or intercep on of
the transmi ed content. This op on has a SIGNIFICANT system overhead. Default se ng is No.
Maximum Delay
- Maximum allowed target delay, in milliseconds. Set to 5000 ms by default.
FEC
- Enables data loss protec on. This op on controls protec on on data transmi ed to the remote end. Disabled
by default.
FEC Delay
- Amount of delay to allow for FEC. Lower packet rates will require higher delay to remain e
ff
ec ve.
Retransmit
- Enables retransmission of lost data. This op on controls protec on on data transmi ed to the remote
end.
Header Compression
- Enables the compression of headers to reduce overhead, especially at lower bitrates.
Default is set to Yes.
Base FEC
- Applies a constant base amount of FEC su
ffi
cient to recover the speci
fi
ed rate of packet loss. Default is
set to 0%.
STUN Server
- Displays IP address of the STUN Server. Default is stun.comrex.com.
Always Connect
- Allows users to a empt to maintain a VPN connec on to a selected peer whenever possible.
Default is set to None.
BRIC NORMAL SETTINGS
IP Port
- This op on de
fi
nes the incoming UDP port—the number to be used for incoming IP connec ons. The
default is
UDP 9000
. Crosslock connec on is defaulted to
UDP 9001
. Note that since most BRIC-Link II codecs
a empt a connec on on this port number, changing it can mean the remote units in the
fi
eld must dial speci
fi
cally
to the new port number in order to connect to the BRIC-Link II. An outgoing call must be made to a speci
fi
c port
number in the form of
IP-ADDRESS:PORT#
. For example, dialing port
UDP 9004
on the Comrex test line is forma ed
70.22.155.131:9004
.
HTTP SETTINGS
Accept Incoming Connec ons
- Users can set BRIC-Link II to listen for and automa cally answer any HTTP incoming
calls. This op on is set to No by default.
IP Port
- This op on de
fi
nes the incoming UDP port—the number to be used for incoming HTTP connec ons. The
default is TCP 8000.
Encoder
- This de
fi
nes the encoder used for HTTP streaming. Default is HE-AAC V2 Stereo 48 kB.
User Agent Blacklist
- List of SIP user agents that are
not
allowed to communicate.
Genre
- Users can de
fi
ne the Genre for HTTP streaming. Default value is set to Live.
Info URL
- Informa onal URL associated with the stream. This se ng is le blank by default.