APPENDIX B BRIC LINK II ON UNIDIRECTIONAL NETWORKS
Under most circumstances, BRIC-Link II requires an IP path in both direc ons for successful connec ons, even when
audio is being sent only one-way. For networks that provide data only in one direc on, it is possible to use
Standard
RTP
mode to establish and maintain these links. This sec on describes how to set that up.
The codec has several compa bility modes under the
Standard RTP
channel mode. The units default to a mode
that is compa ble with the
Luci Live
PC-based encoder. To use
Standard RTP
to make connec ons between Comrex
codecs, this se ng must be changed on both codecs in the link.
• On the BRIC-Link II, click the
System Se ngs Tab
and select “Show Advanced Op ons”.
• Find
Standard RTP Se ngs
and choose to edit the
RTP Compa bility Mode
.
• Change this se ng to
Standard
and click “Apply Changes”.
STANDARD RTP SETTINGS
ENCODE SIDE SETTINGS ONLY
Connec ons of this type must be established from the encoding side of the link. A new pro
fi
le must be built that
uses the
Standard RTP
channel mode in the
Pro
fi
le Manager Tab
. Choose an outgoing encoder along with any
other special a ributes in the Pro
fi
le Se ngs. Name the pro
fi
le something descrip ve like “Simplex”. (See
page
32
for more details on crea ng a new pro
fi
le.)
Next, create an outgoing Remote entry in the
Connec ons Tab
. Apply the new pro
fi
le to that entry. Any connec on
made with that entry will connect in a unidirec onal fashion.
DECODE SIDE SETTINGS ONLY
Enable “Show Advanced Se ngs” in the
System Se ngs Tab
for the receiving unit. Under the
Standard RTP
Se ngs
,
fi
nd the
Return Channel Enable
op on. Disable the return channel and click “Apply Changes”. This will
ensure that no channel will be established in the direc on to the encoder.
FULL TIME OR TRIGGERED CONNECTIONS
A Remote entry using a unidirec onal pro
fi
le can s ll u lize the tools required for automa c connec on.
To set up a connec on to be “always ac ve” (i.e., reconnect in the case of power outage or network failure), choose
that connec on on the
System Se ngs Tab
as the
Always Connect To
loca on.
To trigger the connec on when an external contact is closed, choose the connec on under one of the
Contact
Closure
se ngs on the
System Se ngs Tab
.