53
FieldSmart
®
Fiber Active Cabinet (FAC) 3200
__________________________________________________________
Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • [email protected]
Manual 020421 REV A - Jan 2019
Insert the telco hex key into the door’s upper hex-pin latch.
Turn the key counter-clockwise to disengage the latch.
Repeat Steps 1 and 2 to disengage the lower latch.
Swing the door open until the wind brace engages.
On a powered cabinet, pull the alarm switch plunger to disable reporting of the intrusion alarm.
Note:
Do not rotate the switch plunger. Rotating the plunger may damage the switch.
Step 1:
Step 2:
Step 3:
Step 4:
Step 5:
To open a cabinet door
Operating Cabinet Doors
The cabinet has hinged front, rear, and side doors, each equipped with two telco hex-pin latches and a padlock hasp for
security. Open and close the doors using a Clearfield -supplied telco hex key.
Each door is equipped with an alarm switch that monitors the position of the door. When you open a door on an in-service
cabinet, an intrusion alarm reports through the equipment. Pull the switch plunger to disable the alarm reporting while you
are working on the cabinet. The alarm switch is located at the upper corner of the door frame.
Cabinet Doors