Replacing Parts and Equipment
This section describes how to replace worn or failed parts and equipment in the cabinet.
Removing a Cabinet Door
You can remove the doors from the cabinet for convenience during installation or maintenance activities, or to replace a
door.
Replacing a cabinet door may become necessary if:
• A door becomes damaged.
• A heat exchanger fails or becomes damaged.
• Cooling capacity must be increased to support additional lines or equipment (replacing a 750W heat exchanger door
with an 1850W heat exchanger door).
You can replace cabinet doors in the field without impacting service.
CAUTION!
Handle cabinet doors with care to avoid personal injury or damage to the door. Clearfield recom
-
mends using two people to perform this task.
To remove a cabinet door
For a rear door, disconnect the heat exchanger power & alarm cable.
Disconnect the ground strap from the door by removing the hex nut. Save the nut to re-attach the strap to the
new door.
Remove the nut, bolt, and washer fastening the wind brace to the bracket inside the door frame.