Proprietary Information: Not for use or disclosure except by written agreement with Clearfield.
40
FieldSmart
®
Fiber Active Cabinet (FAC) 3200
Installation Manual
_________________________________________________________
Preparing the Site
At the installation site, verify the following:
• The pole is installed and plumb.
• The pole meets the cabinet mounting
requirements
.
Trench out conduit paths to the pole from the cable feeder location.
Place the cable conduits into the conduit trench. Allow the conduit to extend above ground near the pole to the
approximate height of the base platform. Refer to the
pole mounting guidelines
for conduit sizes and locations.
Note:
The minimum height of 76 inches has the bottom of the mounting assembly standing flush with the
ground (elevates the cabinet approximately 16 inches above the ground). To elevate the cabinet higher than
16 inches above ground, use a pole with sufficient additional height.
Route the earth ground wire through the conduit trench (from the ground electrode). Pull six feet of wire above
ground and position it adjacent to the pole.
Backfill the conduit trench with soil.
Step 1:
Step 2:
Step 3:
Step 4:
Step 5:
Prepare the site for installation of a pole-mounting kit. A general practice is described below for reference. Adapt the
instructions as needed for local requirements, practices, or conditions.
To prepare the site for a pole mount installation