Calibration Factors
1. Alarm Setting
The
ALARM SETTING
calibration factor is used to set
the delay time for triggering the audible alarm*.
This delay can be changed from 0 – 6 seconds.
1. To set the
ALARM SETTING
Cal factor: Place
the SmartFlow II in Calibration mode by placing
the rotary dial to
TARGET RATE
and hold the
CAL
and
INC
buttons together until the console
reads SET and the red Warning
LED
light
is flashing.
2. Move the rotary dial to
ALARM SETTING
position. In the Data Display window, the DE-
LAY SECONDS are displayed. In the Application
Rate Window, CAL is displayed.
3. Use the
INC/DEC
buttons to increase or
decrease the time.
4. Rotate the rotary dial to
TARGET RATE
, press
and hold the
CAL
button for 3 seconds to save
the change and exit Calibration mode.
*NOTE:
This delay setting only affects
the audible alarm, it does not affect any
visual alarm (warning LED). It also does
not affect the Tank alarm (slow beeping)
of the Min/Man speed alarm (fast
beeping). Example: Whenever there is
more than 10% error in the application
rate, the Warning LED will turn on (not
affected by this setting), but the audible
alarm will not turn on for another
(delay value) seconds. Therefore, if
the SmartFlow II has settled on target
within (delay value) seconds, the
audible alarm will not turn on. This
temporary delay in sounding the
Audible Alarm helps to prevent it from
becoming a nuisance alarm (where user
may be tempted to shut it off).
ALARM
SETTING
CALIBRATION