76
SMARTFLOW II
Rotary Dial Functions (Cont.)
6. Rotary Dial Position: TANK
Function: Amount of Liquid in the Tank
The
TANK
position shows the amount of liquid
remaining in the tank, to the nearest tenth of a
gallon or liter. An alarm (see below) will be given
when the Tank level equals or drops below the Set
Point cal factor (default 2.0 gallons or 7.5 liters) while
in
VARIABLE, CONTINUOUS
or
OFF
mode. This alerts
the user that the Tank is low whether he is spraying
or stopped. The user can stop the audible and visual
Tank alarm my momentarily pressing the
RESET
button (while in any position).
If a flow signal is present then Tank continues
decrementing while in while in the
VARIABLE,
CONTINUOUS
or
OFF
mode.
The Tank volume can be adjusted by setting the Spray
switch to
OFF
and then using the
INC
or
DEC
buttons to
adjust it from 0.0 – 6553.5 gallons or liters. For safety
this can only be done while the spray switch is in
OFF
.
Adjusting the Tank volume to any value greater than
zero will always activate the Tank Alarm function.
Adjusting it to 0.0 will disable and clear the Tank Alarm.
Once activated, the alarm will beep On and Off slowly,
the Warn
LED
will turn on and the Application Rate
display will alternate between
FILL
and normal until
the user adjusts the Tank value above the
TANK ALARM
SET POINT
(alarm will stop) or back to 0.0 to disable it.
The Tank value cannot be changed wile in Cal mode
or Special Cal mode, but it can be changed while in
Test Speed mode.
The
FILL
message will not flash while in Cal mode
or Special Cal mode.
NOTE:
Setting the Spray switch to OFF will
stop the 10% Rate Error alarm (steady tone)
but will not stop the Tank Alarm. If the
user clears the Tank alarm by pressing the
RESET button it will stay cleared even if
the SmartFlow II power is turned on and off.
CONTROL PANEL FUNCTIONS