120
SMARTFLOW II
Always inspect the power connection to the
vehicle and the onboard battery as well as the
SmartFlow II cables for any damage or poor
connections. This should always be the first
check before any additional troubleshooting.
Alarm Indicators
The following indicators can be used as reminders
to the operator to inspect the Sleeve condition:
Sleeve Condition
No-Alarm
(Normal Operation)
Maintenance Alert Timer > 1 minute:
• None
Alarm-Notify
(1 min. Warning)
Maintenance Alert Timer < 1 minute:
• Audible Alarm beeps 3 times, then stops.
• Red LED flashes.
• “ALERT” message shown on Application Rate
display window, alternates with normal display
values/messages.
• Must activate Snooze now (within the minute
warning period) to prevent sprayer shutdown.
Alarm-Active
(Sprayer Shut Down)
Maintenance Alert Timer = 0 (expired):
• Audible Alarm sounds for 3 seconds,
then turns off.
• Red LED flashes.
• Alternation messages “CHECK” and SLEEV”
are shown on Application Rate display window
until Maintenance Alert Timer is reset.
See Resetting after Maint Alert Shutdown, p.118.
ALERT
CHECK
slEEV
TROUBLESHOOTING