SMARTFLOW II
Calibration Factors Overview
The SmartFlow II control has 8 calibration factors:
CALIBRATION FACTOR
ROTARY SWITCH POSITION DESCRIPTION
Alarm Setting
AREA (1) (2) (3)
Sets the delay time for triggering the audible alarm.
Speed Cal
DISTANCE
Specifies the distance the vehicle travels between
speed sensor pulses. This enables the SmartFlow II
control to accurately measure speed, distance, area
and application rate.
Cont. Speed
TIME
The speed that is used in Continuous mode.
Test Speed
SPEED
Not a true calibrate factor, but a method of testing
the sprayer.
Target Rate
RATE
Sets the three preset Target Application Rates.
Min Speed
MIN SPEED
The minimum speed allowed in Variable mode. If the
vehicle goes below this speed, the control goes into
Off mode until the speed exceeds this number again.
Max Speed
VOLUME/MINUTE
The maximum speed allowed in Variable mode. If the
vehicle exceeds this speed the control goes into OFF
mode until the speed goes below this number again.
Flow Cal
FLOW CAL
Specifies the number of flow sensor pulses per gallon
applied. This enables the Smart Flow control to
accurately measure total flow, flow per minute,
and application rate.