SMARTFLOW II
Special Calibration Modes (Cont.)
7. Max Snooze Count
Selecting Tank in special calibrate mode displays
“Snoo2” (Snooze) in the Application Rate display
window and allows the user to enter a “Max Snooze
Count” value which can be adjusted from 1 to 20
(Default = 8).
One minute prior to a Maintenance Alert shut down,
an Alert (3 beeps and flashing red light) will notify that
the end of the preset time is near. Snooze must be
triggered during this 1 minute to extend time or sprayer
will shut down. Actuating the Snooze toggle will add
one hour to the timer for each snooze event and will
increment the snooze counter.
The Snooze feature allows the operator to check the
current Snooze Count value, as well as to activate
Snooze. If on a spray mission it is advisable to hit the
snooze to add one hour rather than resetting the timer
fully without actually inspecting or changing the sleeve.
The Snooze feature allows for a customized number of
snooze events, this can be set from 1 to 20. Both “Time
Remaining” and “Snooze Count: values are stored on
power down, so the console will remember the values
if the sprayer is shut down.
Snooze must be triggered during this 1 minute to extend
time or sprayer will shut down. After a shutdown it is
possible to activate a snooze event if the
SPRAY
toggle
is switched to the
OFF
position and then the Snooze
toggle is actuated. Restart of the machine is then
possible without resetting the timer. If Snooze has
been activated a “−" sign is displayed before the
time remaining to indicate that the Sleeve is running
on “borrowed time”.
7a.
SH Lo, Spray Head RPM Low Limit
This feature is
found under the "Tank" selection. The Spray Head Low
Limit is typically 23,400 RPM. This limit defines the
speed at which the pump will stop due to insufficient
spray head RPM. This is meant to maintain desired
droplet size.
SPECIAL CALIBRATION MODES
While still in the Special Calibration
turn the dial from
RATE
position to
TANK
position.
The display in the Application Rate window will read
SH Lo
(spray head low limit). This will be the speed at
which an error is displayed and the pump is stopped due
to insufficient spray head speed or rpm. The default low
limit is 23,400 and will be displayed in the Data Display
window.
SIZE
Tank Fill Size
SET PT
Tank Set Point
Snoo2
Max Snooze Count
ALERT
Maintenance Alert Time
PPR
Pulses Per Revolution Must Remain (2)
SH Hi
Spray Head RPM (High Limit) TYP. 30,000
SH Lo
Spray Head RPM (Low Limit)
tARg
Target Spray Head RPM (Speed) TYP. 28,000
UNIT
Units
ID
Vehicle ID
WJde
Width
C-SPD
Control speed