104
SMARTFLOW II
Special Calibration Modes
When in Special Calibrate mode various words will be
displayed in the Application Rate display window to help
identify which Special Cal Factor you have selected.
To enter
SPECIAL CALIBRATE
mode the user must
turn the machine's Power Switch to
ON
while holding
the
CAL
and the
RESET
button at the same time. The
Data display will show “SPEC" for 1.5 seconds and then
the value of the selected
SPECIAL CALIBRATE
factor.
The
CAL
icon will also be visible in the Data display
window and the red Warn LED will flash to indicate that
these factors can be adjusted.
Various words will be displayed in the Application
Rate display to help identify which Special Cal Factor is
selected.
The
INC
or
DEC
buttons are used to adjust each
SPECIAL CALIBRATE
factor and the longer the
button is pressed the faster the value will change.
All
SPECIAL CALIBRATE
factors will be stored in
Electrically Erasable Programmable Read-Only Memory
(EEPROM)
when exiting
SPECIAL CALIBRATE
mode
(press
CAL
button for 1 sec). They will not be saved
when power is turned off, so if a user accidentally makes
a change he can turn the power off to abort any
SPECIAL CALIBRATE
changes.
The following positions have a Special Cal factor.
The Data display will show dashes and the Application
Rate display will go blank when in an unused
Special Cal position.
SPECIAL CALIBRATION MODES
NOTE:
Some positions on the rotary dial will
direct you to a second feature when the CAL
button is pressed quickly (less than 1 second).
SIZE
Tank Fill Size
SET PT
Tank Set Point
Snoo2
Max Snooze Count
ALERT
Maintenance Alert Time
PPR
Pulses Per Revolution Must Remain (2)
SH Hi
Spray Head RPM (High Limit) TYP. 30,000
SH Lo
Spray Head RPM (Low Limit)
tARg
Target Spray Head RPM (Speed) TYP. 28,000
UNIT
Units
ID
Vehicle ID
WJde
Width
C-SPD
Control speed