126
SMARTFLOW II
Messages and Warnings
The Consoles will display the following messages (in alphabetical order) for the conditions indicated:
DISPLAY
CONDITION
bAd CAL
if EEPROM Check Sum equals zero or fails at
power up.
CAL
Shown in App Rate display to help indicate Cal mode
is selected.
CLEAr
Warning that user is about to Clear a counter.
C-SPd
In App Rate display to indicate the control algorithms
‘Control Speed’ in Special Cal Mode is selected.
Err 0
Error code in App Rate display where n = 1 to 5.
FAIL
Failed to reprogram the Flash.
FILL
Flashed in App Rate display to indicate the Tank level
is equal or less than Tank Set Point.
FLASH
Console is ready to have the Flash reprogrammed.
FLUSH
In App Rate display when performing Flush operation.
60UAr
User is trying to adjust Test Speed while
in CONTINUOUS mode and needs to
“Go to VARIABLE” mode.
HI SPEEd
In the App Rate display indicates the ground
speed exceeds the Max Speed cal factor while in
VARIABLE mode.
Id
In App Rate display to indicate Special Cal ‘Vehicle ID’
is selected.
LOAd
User has loaded Default Cal Factors. (Metric if in
Area mode).
Lo P
Low Power. Pump is stopped.
Lo SPEEd
In the App Rate display indicates the ground speed
has dropped below the Min Speed cal factor while
in VARIABLE mode.
OFF
In App Rate display when Spray toggle switch is in
OFF mode.
OFL
Overflow in any display (greater than 99999).
PASS
Correctly finished reprogramming the software.
PCOFF
In App Rate display when VRA Controller selects
“PC Off” mode by sending Target = 0.
SEE
User has started ‘View and Change’ Cal mode.
TROUBLESHOOTING