99
SMARTFLOW II
Calibration Factors
8. Flow Cal
In the Flow Cal position the current Flowmeter Calibrate
factor value will be displayed. This specifies the
number of flow sensor pulses per gallon applied. This
enables the SmartFlow II control to accurately measure
total flow, flow per minute and application rate. The
Flowmeter calibrate factor is in (English or Metric).
1. To set the Flow Cal factor: Place the SmartFlow II
in Calibration mode by placing the rotary dial to
TARGET RATE
and hold the
CAL
and
INC
buttons
together until the console reads SET and the red
Warning LED light is flashing.
2. Place the
RATE
toggle switch to
RATE 1
.
3. Move the rotary dial to
FLOW CAL
position
4. Set the correct rate* for your product’s fluid oz./
min. per the product label by using the
INC/
DEC
buttons. This rate will be displayed in the
Application Rate display window.
5. The selected rate and current units are displayed
in the in the Data display window and the
current target application rate is displayed in the
Application Rate display window.
FLOW
CAL
*HINT:
Choose your fluid oz./min. per
product label, then divide by 6 to give
you your correct target rate to program
the console.
CALIBRATION