84
SMARTFLOW II
Toggle Switches (Cont.)
CONT:
The
CONTINUOUS
mode can be used to spray while
stationary or parked. In the position the
MAN
icon turn
on in the Application Rate display window. The Speed
is assumed to be “continuous” or a constant speed. The
SmartFlow II will measure the flow (but not the speed)
and automatically adjust the sprayer to maintain
the selected Target Rate* (1, 2, or 3) on a “continuous”
speed even though the actual
CONTINUOUS
ground
speed may vary or is stopped. Only the Flow is mea-
sured to compute and control the application rate (Oz/
Acre) independent of actual ground speed.
When switched from
OFF
to the
CONTINUOUS
mode,
the SmartFlow II will turn on and off as described in
VARIABLE
mode.
The “Continuous” speed Calibration value can be set
from 2.0 – 45.0 mph (or kph) and the same speed is
used for all 3 Rates. If the “speed” position is selected
on the rotary switch, it will flash the “Continuous
Speed” Calibration factor rather than show the actual
speed.
OFF:
In the
OFF
mode the Application Rate display will
show “
OFF
” and the
AUTO
and
MAN
icons will turn
off. The SmartFlow II will stop the sprayer.
NOTE:
The Target Rate cannot be adjusted by
using the INC and DEC buttons.