97
SMARTFLOW II
Calibration Factors (Cont.)
6. Min Speed
MIN SPEED
displays the “Minimum Speed” which can
be adjusted from “off” to 0.1 to 45.0 mph or kph. If
used, the user must ensure that Min Speed is less than
Max Speed (if used) or else the sprayer will never turn
on.
Min Speed is used to stop the sprayer (and Distance,
Area and Time counting) when the ground speed drops
below this limit (in the
VARIABLE
mode only).
1. To set the
MIN SPEED
factor: Place the SmartFlow
II in Calibration mode by placing the rotary dial to
TARGET RATE
and hold the
CAL
and
INC
buttons
together until the console reads SET and the red
Warning LED light is flashing.
2. Move the rotary dial to
MIN SPEED
position.
‘Lo’ is displayed in the in the Data display window
and the current Minimum Speed is displayed
in the Application Rate display window.
3. Use the
INC/DEC
buttons to increase or decrease
the speed.
4. Rotate the rotary dial to
TARGET RATE
, press
and hold the CAL button for 3 seconds to save
the change and exit Calibration mode.
MIN
SPEED
CALIBRATION