20-50
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 20 DLPs D300 to D399
DLP- D341 Change Line and Threshold Settings for the DS3i-N-12 Cards
describes the values on the Provisioning > SDH Thresholds tab for the DS3i-N-12 cards.
Note
The threshold value appears after the circuit is created.
Step 7
Return to your originating procedure (NTP).
Table 20-20
Electrical Path Options for the DS3i-N-12 Cards
Parameter
Description
Port
(Display only) Port number; Port 1 to 12.
CVP
Coding violations - path. Available for DS3 Pbit, Near End only; and for DS3
CPbit, Near End and Far End.
ESP
Errored seconds - path. Available for DS3 Pbit, Near End only; and for DS3
CPbit, Near End and Far End.
SESP
Severely errored seconds - path. Available for DS3 Pbit, Near End only; and
for DS3 CPbit, Near End and Far End.
SASP
Severely errored frame/alarm indication signal - path. Available for DS3 Pbit,
Near End only; and for DS3 CPbit, Near End and Far End.
UASP
Unavailable seconds - path. Available for DS3 Pbit, Near End only; and for
DS3 CPbit, Near End and Far End.
AISSP
Alarm indication signal seconds - path. Available for DS3 Pbit, Near End only;
and for DS3 CPbit, Near End and Far End.
15 Min radio button
Clicking this radio button and then clicking Refresh will cause the threshold
values on this tab to display for 15-minute intervals.
1 Day radio button
Clicking this radio button and then clicking Refresh will cause the threshold
values on this tab to display for 1-day intervals.
Table 20-21
SDH Threshold Options for DS3i-N-12 Cards
Parameter
Description
Port
(Display only) Port number; 1 to 12.
ES
Errored seconds. Available for Near End and Far End, VC LO or VC4.
SES
Severely errored seconds. Available for Near End and Far End, VC LO or
VC4.
EB
Errored blocks. Available for Near End and Far End, VC LO or VC4.
UAS
Unavailable seconds. Available for Near End and Far End, VC LO or VC4.
BBE
Background block errors. Available for Near End and Far End, VC LO or
VC4.
15 Min radio button
Clicking this radio button and then clicking Refresh will cause the threshold
values on this tab to display for 15-minute intervals.
1 Day radio button
Clicking this radio button and then clicking Refresh will cause the threshold
values on this tab to display for 1-day intervals.
Summary of Contents for ONS 15454 SDH
Page 26: ...Tables vi Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 ...
Page 62: ...xxii Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Page 64: ...xxiv Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Page 66: ...xxvi Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Page 860: ...Index IN 28 Cisco ONS 15454 SDH Procedure Guide R6 0 78 17194 01 ...