Chapter 6 Create Circuits and Low-Order Tunnels
NTP- D323 Create an Automatically Routed High-Order Circuit
h.
Review the circuit constraints. To change the circuit routing order, choose a node in the
Required Nodes/Lines lists and click the
Up
or
Down
buttons to change the circuit routing order.
Click
Remove
to remove a node or span.
Step 19
If you selected Review Route Before Creation in
, complete the following substeps; otherwise,
continue with
:
a.
Click
Next
.
b.
Review the circuit route. To add or delete a circuit span, choose a node on the circuit route. Blue
arrows show the circuit route. Green arrows indicate spans that you can add. Click a span arrowhead,
then click
Include
to include the span or
Remove
to remove the span.
c.
If the provisioned circuit does not reflect the routing and configuration you want, click
Back
to
verify and change circuit information. If the circuit needs to be routed to a different path, see the
“NTP-D324 Create a Manually Routed High-Order Circuit” procedure on page 6-60
to assign the
circuit route yourself.
Step 20
If you selected Review Route Before Creation in
Next
. If not, continue with
. View
the route in the Route Review/Edit window. As necessary, click
Add MS-SPRing DRI
to add another
DRI. Click
Remove
to remove a DRI assignment. Click the
Included Spans
tab to view the spans. The
map graphic updates as you apply changes.
Step 21
Click
Finish
. One of the following occurs, based on the circuit properties that you provisioned in the
Circuit Creation dialog box:
•
If you entered more than 1 in the Number of Circuits field and selected Auto-ranged, CTC
automatically creates the number of circuits entered in Number of Circuits. If auto-ranging cannot
complete all the circuits, for example, because sequential ports are unavailable on the source or
destination, a dialog box appears. Set the new source or destination for the remaining circuits, then
click
Finish
to continue auto-ranging. After completing the circuits, the Circuits window appears.
•
If you entered more than 1 in Number of Circuits and did not choose Auto-ranged, the Circuit
Creation dialog box appears so you can create the remaining circuits. Repeat Steps
through
for
each additional circuit. After completing the circuits, the Circuits window appears.
Step 22
In the Circuits window, verify that the circuits you created appear in the circuits list.
Step 23
Complete the following as necessary. Skip this step if you built a test circuit.
a.
Complete the
“NTP-D62 Test High-Order Circuits” procedure on page 6-66
b.
Complete the
“NTP-D149 Test G-Series Circuits” procedure on page 6-95
.
Stop. You have completed this procedure.
Summary of Contents for ONS 15454 SDH
Page 26: ...Tables vi Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 ...
Page 62: ...xxii Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Page 64: ...xxiv Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Page 66: ...xxvi Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Page 860: ...Index IN 28 Cisco ONS 15454 SDH Procedure Guide R6 0 78 17194 01 ...