20-49
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 20 DLPs D300 to D399
DLP- D341 Change Line and Threshold Settings for the DS3i-N-12 Cards
describes the values on the Provisioning > Line Thresholds tab for the DS3i-N-12 cards.
Only near-end line threshold options are supported for this card.
describes the parameters on the Provisioning > Elect Path Thresholds tab for the DS3i-N-12
cards.
Service
State
(Display only) Identifies the
autonomously generated state that gives
the overall condition of the port. Service
states appear in the format: Primary
State-Primary State Qualifier, Secondary
State. For more information about
service states, refer to the
“Administrative and Service States”
appendix of the
Cisco ONS 15454 SDH
Reference Manual
.
•
Unlocked-enabled—The port is fully
operational and performing as
provisioned.
•
Unlocked-disabled,automaticInService—
The port is out-of-service, but traffic is
carried. Alarm reporting is suppressed.
The ONS node monitors the ports for an
error-free signal. After an error-free
signal is detected, the port stays in the
Unlocked-disabled,automaticInService
state for the duration of the soak period.
After the soak period ends, the port
service state changes to
Unlocked-enabled.
•
Locked-enabled,disabled—The port is
out-of-service and unable to carry traffic.
•
Locked-enabled,maintenance—The port
is out-of-service for maintenance. Alarm
reporting is suppressed, but traffic is
carried and loopbacks are allowed.
AINS Soak
Sets the automatic in-service soak
period.
•
Duration of valid input signal, in hh.mm
format, after which the card becomes in
Unlocked-enabled automatically
•
0 to 48 hours, 15-minute increments
Table 20-18
Line Options for the DS3i-N-12 Cards (continued)
Parameter
Description
Options
Table 20-19
Line Threshold Options for the DS3i-N-12 Cards
Parameter
Description
Port
(Display only) Port number; 1 to 12.
CV
Coding violations.
ES
Errored seconds.
SES
Severely errored seconds.
LOSS
Loss of signal seconds; number of one-second intervals containing one or
more LOS defects.
15 Min radio button
Clicking this radio button and then clicking Refresh will cause the
threshold values on this tab to display for 15-minute intervals.
1 Day radio button
Clicking this radio button and then clicking Refresh will cause the
threshold values on this tab to display for 1-day intervals.
Summary of Contents for ONS 15454 SDH
Page 26: ...Tables vi Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 ...
Page 62: ...xxii Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Page 64: ...xxiv Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Page 66: ...xxvi Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Page 860: ...Index IN 28 Cisco ONS 15454 SDH Procedure Guide R6 0 78 17194 01 ...