18-32
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 18 DLPs D100 to D199
DLP- D140 Change the Node Name, Date, Time, and Contact Information
Note
To monitor the J1 path on STM-N ports, the circuit endpoints must be transmitting VC4 J1 and not
VC3 J1.
Step 1
From the View menu, choose
Go to Other Node
. In the Select Node dialog box, choose the node where
path trace was provisioned on the circuit source and destination ports.
Step 2
Click
Circuits
.
Step 3
Choose the VC4 circuit that has path trace provisioned on the source and destination ports, then click
Edit
.
Step 4
In the Edit Circuit window, click the Show Detailed Map check box at the bottom of the window. A
detailed circuit graphic showing source and destination ports appears.
Step 5
On the detailed circuit map, right-click the circuit STM-N port (the square on the left or right of the
source node icon) and choose
Edit Path Trace
from the shortcut menu.
Note
The STM-N port must be on a receive-only card listed in
Edit Path Trace menu item does not appear.
Step 6
In the Circuit Path Trace window, enable the path trace expected string by choosing
Auto
or
Manual
from the Path Trace Mode drop-down list:
•
Auto—Uses the first string received from the port at the other path trace end as the current expected
string. An alarm is raised when a string that differs from the baseline is received. For STM-N ports,
Auto is recommended because Manual mode requires you to trace the circuit on the Edit Circuit
window to determine whether the port is the source or destination path.
•
Manual—Uses the Current Expected String field as the baseline string. An alarm is raised when a
string that differs from the Current Expected String is received.
Note
It is not necessary to set the format (16 or 64 bytes) for the expected string; the path trace process
automatically determines the format.
Step 7
If you set the Path Trace Mode field to Manual, enter the string that the STM-N port should receive in
the New Expected String field. To do this, trace the circuit path on the detailed circuit window to
determine whether the port is in the circuit source or destination path, then set the New Expected String
to the string transmitted by the circuit source or destination. If you set the Path Trace Mode field to Auto,
skip this step.
Step 8
Click
Apply
, then click
Close
.
Step 9
Return to your originating procedure (NTP).
DLP-D140 Change the Node Name, Date, Time, and Contact Information
Purpose
This task changes basic information such as node name, date, time, and
contact information.
Tools/Equipment
None
Summary of Contents for ONS 15454 SDH
Page 26: ...Tables vi Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 ...
Page 62: ...xxii Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Page 64: ...xxiv Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Page 66: ...xxvi Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Page 860: ...Index IN 28 Cisco ONS 15454 SDH Procedure Guide R6 0 78 17194 01 ...