19-62
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 19 DLPs D200 to D299
DLP- D257 View Ethernet Utilization PM Parameters
Step 5
View the PM parameter names in the Param column. The current PM parameter values appear in the
Port # columns. For PM parameter definitions, refer to the “Performance Monitoring” chapter in the
Cisco ONS 15454 SDH Reference Manual
.
Note
To clear PM counts, see
“DLP-D459 Clear Selected PM Counts” task on page 21-36
Step 6
Return to your originating procedure (NTP).
DLP-D257 View Ethernet Utilization PM Parameters
Step 1
In node view, double-click the E-Series or G-Series Ethernet card where you want to view PM counts.
The card view appears.
Step 2
Click the
Performance
>
Utilization
tabs.
Step 3
Click
Refresh
. Performance monitoring utilization values appear for each port on the card.
Step 4
View the Port # column to find the port you want to monitor.
Step 5
The Tx and Rx bandwidth utilization values for the previous time intervals appear in the Prev-
n
columns.
For PM parameter definitions, refer to the “Performance Monitoring” chapter in the
Cisco ONS 15454 SDH Reference Manual
.
Note
To clear PM counts, see the
“DLP-D459 Clear Selected PM Counts” task on page 21-36
.
Step 6
Return to your originating procedure (NTP).
Purpose
This task enables you to view line utilization PM counts on an Ethernet
card and port in order to detect possible performance problems.
Tools/Equipment
None
Prerequisite Procedures
DLP-D60 Log into CTC, page 17-49
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Retrieve or higher
Summary of Contents for ONS 15454 SDH
Page 26: ...Tables vi Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 ...
Page 62: ...xxii Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Page 64: ...xxiv Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Page 66: ...xxvi Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Page 860: ...Index IN 28 Cisco ONS 15454 SDH Procedure Guide R6 0 78 17194 01 ...