20-20
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 20 DLPs D300 to D399
DLP- D330 Install 120-Ohm E-1 Cables with Molex 96-Pin LFH Connectors
DLP-D330 Install 120-Ohm E-1 Cables with Molex 96-Pin LFH Connectors
Step 1
Using the cables with Molex 96-pin LFH connectors available from Cisco, connect the male connector
to the female connector on the FMEC card that you want to connect to.
Use
to make the connection from the E-1 96-pin connector for Ports 1 to 21 to the external
balanced 120-ohm E-1 interfaces.
Purpose
This task installs the 120-ohm E-1 cables on FMEC E1-120NP,
FMEC E1-120PROA, and FMEC E1-120PROB cards. Also use this task to
install the 120-ohm E-1 cables on the E1-75/120 conversion panel.
Tools/Equipment
Twisted-pair cables with Molex 96-pin LFH connectors
Prerequisite Procedures
NTP-D220 Install the Power and Signal FMECs, page 1-7
Required/As Needed
As needed
Onsite/Remote
Onsite
Security Level
None
Table 20-6
Pinout for E-1 Interfaces on Ports 1 to 21
Pin
No.
Signal
Name
Wire Color
Pin
No.
Signal
Name
Wire Color
Pin
No.
Signal
Name
Wire Color
Pin
No.
Signal
Name
Wire Color
1
TX 11 N
white-blue
25
RX 11 N
white-blue
49
TX 21 N
black-orange
73
RX 21 N
black-orange
2
TX 11 P
blue-white
26
RX 11 P
blue-white
50
TX 21 P
orange-black
74
RX 21 P
orange-black
3
TX 10 N
white-orange
27
RX 10 N
white-orange
51
TX 20 N
black-green
75
RX 20 N
black-green
4
TX 10 P
orange-white
28
RX 10 P
orange-white
52
TX 20 P
green-black
76
RX 20 P
green-black
5
TX 9 N
white-green
29
RX 9 N
white-green
53
TX 19 N
black-brown
77
RX 19 N
black-brown
6
TX 9 P
green-white
30
RX 9 P
green-white
54
TX 19 P
brown-black
78
RX 19 P
brown-black
7
TX 8 N
white-brown
31
RX 8 N
white-brown
55
TX 18 N
black-slate
79
RX 18 N
black-slate
8
TX 8 P
brown-white
32
RX 8 P
brown-white
56
TX 18 P
slate-black
80
RX 18 P
slate-black
9
TX 7 N
white-slate
33
RX 7 N
white-slate
57
TX 17 N
yellow-blue
81
RX 17 N
yellow-blue
10
TX 7 P
slate-white
34
RX 7 P
slate-white
58
TX 17 P
blue-yellow
82
RX 17 P
blue-yellow
11
TX 6 N
red-blue
35
RX 6 N
red-blue
59
TX 16 N
yellow-orange
83
RX 16 N
yellow-orange
12
TX 6 P
blue-red
36
RX 6 P
blue-red
60
TX 16 P
orange-yellow
84
RX 16 P
orange-yellow
13
TX 5 N
red-orange
37
RX 5 N
red-orange
61
TX 15 N
yellow-green
85
RX 15 N
yellow-green
14
TX 5 P
orange-red
38
RX 5 P
orange-red
62
TX 15 P
green-yellow
86
RX 15 P
green-yellow
15
TX 4 N
red-green
39
RX 4 N
red-green
63
TX 14 N
yellow-brown
87
RX 14 N
yellow-brown
16
TX 4 P
green-red
40
RX 4 P
green-red
64
TX 14 P
brown-yellow
88
RX 14 P
brown-yellow
17
TX 3 N
red-brown
41
RX 3 N
red-brown
65
TX 13 N
yellow-slate
89
RX 13 N
yellow-slate
18
TX 3 P
brown-red
42
RX 3 P
brown-red
66
TX 13 P
slate-yellow
90
RX 13 P
slate-yellow
19
TX 2 N
red-slate
43
RX 2 N
red-slate
67
TX 12 N
violet-blue
91
RX 12 N
violet-blue
20
TX 2 P
slate-red
44
RX 2 P
slate-red
68
TX 12 P
blue-violet
92
RX 12 P
blue-violet
21
TX 1 N
black-blue
45
RX 1 N
black-blue
69
—
—
93
—
—
22
TX 1 P
blue-black
46
RX 1 P
blue-black
70
—
—
94
—
—
Summary of Contents for ONS 15454 SDH
Page 26: ...Tables vi Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 ...
Page 62: ...xxii Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Page 64: ...xxiv Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Page 66: ...xxvi Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Page 860: ...Index IN 28 Cisco ONS 15454 SDH Procedure Guide R6 0 78 17194 01 ...