20-46
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 20 DLPs D300 to D399
DLP- D340 Change Line and Threshold Settings for the E3-12 Cards
describes the values on the Provisioning > Elect Path Thresholds tab for the E3-12 cards.
describes the values on the Provisioning > SDH Thresholds tab for the E3-12 cards.
Note
The threshold value appears after the circuit is created.
Step 7
Return to your originating procedure (NTP).
Table 20-16
Electrical Path Threshold Options for E3-12 Cards
Parameter
Description
Port
(Display only) E-3 ports; 1 to 12.
ES
Errored seconds.
SES
Severely errored seconds.
UAS
Unavailable seconds.
15 Min radio button
Clicking this radio button and then clicking Refresh will cause the threshold
values on this tab to display for 15-minute intervals.
1 Day radio button
Clicking this radio button and then clicking Refresh will cause the threshold
values on this tab to display for 1-day intervals.
Table 20-17
SDH Threshold Options for E3-12 Cards
Parameter
Description
Port
(Display only) E-3 ports; 1 to 12.
ES
Errored seconds.
SES
Severely errored seconds.
EB
Errored blocks.
UAS
Unavailable seconds.
BBE
Background block errors.
15 Min radio button
Clicking this radio button and then clicking Refresh will cause the threshold
values on this tab to display for 15-minute intervals.
1 Day radio button
Clicking this radio button and then clicking Refresh will cause the threshold
values on this tab to display for 1-day intervals.
Summary of Contents for ONS 15454 SDH
Page 26: ...Tables vi Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 ...
Page 62: ...xxii Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Page 64: ...xxiv Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Page 66: ...xxvi Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Page 860: ...Index IN 28 Cisco ONS 15454 SDH Procedure Guide R6 0 78 17194 01 ...