2-11
Cisco DPA 7630/7610 Voice Mail Gateways Administration Guide
78-11069-03
Chapter 2
Choosing an Integration Mode
Using the Hybrid Integration Mode
•
Line C (ports 17-24) connects to the Definity system for setting the MWIs.
Ensure these MWI lines have a one-to-one correspondence with the MWI
lines in Line B, in both quantity and physical location. The remaining ports
on Line C are not available. You cannot use them to connect to the Octel
system.
For example, if you assign the last four ports on Line B (ports 13, 14, 15, and
16) to be Octel MWI lines, you must also assign the last four ports on Line C
(ports 21, 22, 23, and 24) to be Definity MWI lines. The remaining ports on
Line C (ports 20, 19, 18, and 17) are not used.
DPA 7610
To use this configuration, all MWI lines for the Meridian 1 and
Cisco CallManager systems must pass through the DPA 7610 (see
Figure 2-6
):
Figure 2-6
Logical Connections of Hybrid Integration on the DPA 7610
Octel
Meridian 1 PBX
1
1
2
3
2
3
Ports 24-1
DPA 7610
Assign these 4 lines
(ports 16, 15, 14, 13) to
handle MWI commands.
Use the same number of
lines and corresponding
ports as those connected
to the Meridian 1 PBX.
Assign these 4 lines
(ports 24, 23, 22, 21)
to handle MWIs on the
Meridian 1.
Assign these 12 lines
(ports 1-12) to handle
either incoming calls or
outgoing calls. Do not
enable incoming and
outgoing calls on the
same line.
49958