3-5
Cisco DPA 7630/7610 Voice Mail Gateways Administration Guide
78-11069-03
Chapter 3
Installing the DPA 7630/7610
Installing the DPA 7630/7610
•
Ethernet cable for connection to an Ethernet port
•
Telco cabling for connection to the Octel and PBX systems
Installing the DPA 7630/7610
You have the option of installing the DPA 7630/7610 in a 19-inch rack or setting
it on a shelf or other flat surface. Refer to these sections for detailed instructions:
•
Installing the DPA 7630/7610 in a Rack, page 3-5
•
Setting the DPA 7630/7610 on a Shelf or Table, page 3-7
Installing the DPA 7630/7610 in a Rack
The DPA 7630/7610 includes the brackets and screws required to install it in a
19-inch rack. Follow these instructions to install it safely and securely.
Warning
To prevent bodily injury when mounting or servicing this unit in a rack, you must
take special precautions to ensure that the system remains stable. The
following guidelines are provided to ensure your safety:
•
This unit should be mounted at the bottom of the rack if it is the only unit in
the rack.
•
When mounting this unit in a partially filled rack, load the rack from the
bottom to the top with the heaviest component at the bottom of the rack.
•
If the rack is provided with stabilizing devices, install the stabilizers before
mounting or servicing the unit in the rack.
Attaching the Brackets
The chassis comes with brackets for use with a 19-inch rack. To install the chassis
in a rack, attach the brackets in one of the following ways:
•
With the front panel forward (see
Figure 3-1
)
•
With the rear panel forward (see
Figure 3-2
)