Configuring Call Handling
How to Configure Cisco Unified SIP SRST
167
Cisco Unified SCCP and SIP SRST System Administrator Guide
OL-13143-04
In a typical Cisco Unified SIP SRST setup, the
call-forward b2bua mailbox
command is not used;
however, it is likely to be used in a Cisco Unified SIP Communications Manager Express (CME)
environment. Detailed procedures for configuring the
call-forward b2bua mailbox
command are found
in the
Cisco Unified Communications Manager (CallManager)
documentation on Cisco.com.
SUMMARY STEPS
1.
enable
2.
configure
terminal
3.
voice register pool
tag
4.
call-forward b2bua
all
directory
-
number
5.
call-forward b2bua
busy
directory
-
number
6.
call-forward b2bua
mailbox
directory
-
number
7.
call-forward b2bua
noan
directory
-
number
timeout
seconds
8.
end
DETAILED STEPS
Command or Action
Purpose
Step 1
enable
Example:
Router> enable
Enables privileged EXEC mode.
•
Enter your password if prompted.
Step 2
configure terminal
Example:
Router# configure terminal
Enters global configuration mode.
Step 3
voice register pool
tag
Example:
Router(config)# voice register pool 15
Enters voice register pool configuration mode.
•
Use this command to control which phone registrations
are accepted or rejected by a Cisco Unified SIP SRST
device.
Step 4
call-forward b2bua all
directory-number
Example:
Router(config-register-pool)# call-forward
b2bua all 5005
Enables call forwarding for a SIP back-to-back user agent
(B2BUA) so that all incoming calls are forwarded to
another non-SIP station extension (that is, SIP trunk, H.323
trunk, SCCP device or analog/digital trunk).
•
directory-number
: Telephone number to which calls are
forwarded. Represents a fully qualified E.164 number.
Maximum length of the telephone number is 32.
Step 5
call-forward b2bua busy
directory-number
Example:
Router(config-register-pool)# call-forward
b2bua busy 5006
Enables call forwarding for a SIP B2BUA so that incoming
calls to a busy extension are forwarded to another extension.
•
directory-number
: Telephone number to which calls are
forwarded. Represents a fully qualified E.164 number.
Maximum length of the telephone number is 32.