20
Cisco IOS XE 3S Release Notes for the Cisco ASR 903 Router
OL-26630-08
Chapter
Caveats in Cisco IOS XE 3.10S Releases
Conditions:
This issue is observed when you have ATM and IMA configured and perform an SSO.
IOMd crashes and the IM goes out of service.
Workaround:
There is no workaround.
•
CSCue54997
Symptom:
The system accepts two input clock sources from the same OC3 IM although the system
supports only one input clock source per OC3 IM. This results in clock failures.
Conditions:
This issue is observed when two input clock sources are accepted from the same OC3
IM although the framer on the IM can support only one clock source.
Workaround:
Do not configure the second input clock source from the same OC3 IM.
Alternatively, remove both OC3 clock sources and configure the desired OC3 controller.
•
CSCue57671
Symptom:
Router crashes while running the REP configuration.
Conditions:
This issue is observed while removing the REP configuration from the interface.
Workaround:
There is no workaround.
•
CSCue66019
Symptom:
The router displays MLPPP interface errors.
Conditions:
This issue is observed when there is more than 90% line rate traffic with mix MTU
patterns.
Workaround:
There is no workaround.
•
CSCue67835
Symptom:
OSPF flaps when you set the dead interval timer as 6 seconds and hello interval as 2
seconds.
Conditions:
This issue is observed when you perform an SSO.
Workaround:
Use the default OSPF hello timers.
•
CSCue72481
Symptom:
The same interface accepts an IP address and a MEP.
Conditions:
This issue is observed when you configure an IP address and a MEP to the same
interface.
Workaround:
There is no workaround.
•
CSCue83621
Symptom:
Policy map stops working after you dynamically remove class default class.
Conditions:
This issue is observed when the policy map is attached to the target and the class default
of the top level is deleted dynamically, the policy stops working.
Workaround:
Detach and reattach the policy map on the target.
•
CSCue89503
Symptom:
The power supply status reports critical after you remove and insert the power supply.
Conditions:
This issue is observed after performing multiple OIRs.
Workaround:
There is no workaround.
•
CSCuf01120