Scheda carica batteria

This device allows the propulsion unit to work during blackouts.
•   The programmer has a built in charger for an 

NiMH 24V

 battery that is 

managed by a dedicated micro controller. The control chip adjusts the 

voltage according to the condition of the connected battery. 

To avoid the risk of overheating only use the battery supplied 

by the manufacturer (

SPN

 

999540

).

If the battery shows signs of damage it must be replaced 

immediately.

The battery must only be installed/removed by qualified 

personnel. Used batteries must not be thrown into domestic 

rubbish bins and they must be disposed of according to the 

local standards and regulations in force.

•  The unit returns to normal operation once the power supply brought back 

on line.  To use the battery again it must first be allowed to recharge. 

  The battery charge time with a battery in good condition can take up 

to a maximum of 

16 hours

. If the time required is greater you should 

consider replacing the battery. You are however advised to replace the 

battery every three years.

•  When the door has stopped, the controlled external devices (

CTRL 24 

Vdc

) do not receive power in order to increase the autonomy of the bat-

tery. When a command is received however (

via radio

 or 

via cable

) the 

programmer sends power to the controlled external devices and checks 

their security status. It follows therefore that the command will be carried 

out (security devices at rest) with a one second delay to give time to restore 

the correct operation of the devices. If after this period a security device 

is found to be in alarm the command will not be carried out, power to the 

external devices will be cut off and the programmer will return to stand-by.

Note!

 If you wish to use an external receiver it must be wired to the binding 

posts 16-17 (fig. 1) otherwise a command sent 

via radio

 will not be able 

to activate the door.
•  The self-sufficiency of the system when it is running on battery power 

is dependent on the ambient conditions and on the load connected at 

binding posts 16-17 (power is always routed there during blackouts).

When the battery is completely flat (during blackouts) the pro-

grammer will lose the position of the door and therefore when 

power returns (after the first command given) you will have to 

carry out the repositioning procedure (see page 20). For this 

reason you should avoid leaving the 

electronic programmer 

without power

 for lengthy periods (more than two days).

•  It is not possible to enter the programming mode when running off 

battery power.

•  During blackouts the battery supplies power to both the logic and the 

motor control parts of the programmer. 

  For this reason during battery powered operation the voltage applied 

to the motor is inferior to the voltage supplied during normal operation 

and the motor will therefore work slower and will not decelerate when 

ªapproaching the travel limits.

Slot-in battery charger

The LED 

L3

 indicates the function mode as follows:

 Off

:  missing batteries or the electronic programmer is run-

ning off battery power (during a blackout). During the 

first 10 seconds of operation from the start up of the 

electronic programmer the battery charger is blocked. 

After this period has elapsed it may either start self-

diagnostics  (indicated by a lengthy flashing of the Led) 

or it will start recharging (Led continuously lit);

 

Brief flashing: 

voltage variation has been detected at the battery 

charger binding posts (e.g. when the batteries are 

being connected or removed);

 

Single flashing: 

this repeats every 2 seconds indicating that the bat-

teries are being topped up to maintain their level;

 

Remains lit: 

the batteries are charging. The charge time depends on 

a number of factors and can last up to 16 hours. Using 

the motor will increase the time needed for charging.

Battery check

With the gate in the completely closed position and the display switched off. 

Check that LED "

L3

" (battery charging) is giving off 

"one flash at a time"

.

Switch off the power at the mains and make sure that the display indicates 

that it is working off battery power and that it is fully charged

. Give a 

movement command and measure the overall voltage. The reading should 

be at least 

22 Vdc

.

Summary of Contents for CC242ETOP

Page 1: ...lectrique exemple d installation Page 3 Consignes importantes Page 20 Branchement lectrique Pages 20 21 Proc d de programmation Page 22 23 Menu de visualisation Page 24 Commande via radio Page 24 25 M...

Page 2: ...pliqu e sur l emballage ou sur la notice d installation et d utilisation fournie avec le produit mettez le programmateur lectronique hors tension remplacez le module de m moire 24 LC16 S449 par le mod...

Page 3: ...RL 24Vdc CMN LS LP CMN LC CH2 ELS 12Vdc CMN F4 10 A J3 F3 10 A BATTERY CHARGER J1 R1 J6 J2 J4 L2 ANS400 Enable Disable ANQ800 1 3 4 5 6 1 2 Bl Gr Gy Yw M1 ENCODER 1 Rd Bk M1 3 4 5 6 1 2 Bl Gr Gy Yw M2...

Page 4: ...o scariche si verifica laperditadelcontrollodellaposizionedell antaconconseguente segnalazionediallarmeenecessit diriposizionamento Controllare quindi l efficienza delle batterie ogni sei mesi vedi pa...

Page 5: ...gnalazione fotocellule di stop FS 3 FS S4 Segnalazione costa sensibile CP 3 CP S5 Segnalazione tasto di apertura TA TA S6 Segnalazione tasto di chiusura TC TC S7 Segnalazione comando sequenziale TD TD...

Page 6: ...IN STOP TEST FI ON OFF TEST FS ON OFF TEST FS ON OFF SFASAM APERTURA ON OFF ELETTROSERRATURA ON OFF TEST FI ON OFF TEST FS ON OFF SFASAMENTO IN APERTURA ON OFF SFASAM APERTURA ON OFF ELETTROSERRATURA...

Page 7: ...TAL INT COSTA TB FI FS CP TA TD TC TAL INT SENS PROG OK per confermare PREMERE sul trasmettitore il canale da memorizzare PREMERE sul trasmettitore lo stesso canale per memorizzare PROG OK per conferm...

Page 8: ...alla voce CANCEL TOTALE Memorizzazione di ulteriori canali via radio solo S449 S486 La memorizzazione pu essere anche attivata via radio senza aprire la scatola dove alloggiata la centralina se l imp...

Page 9: ...essere spostate a mano una volta ribloc cati il programmatore provveder al ripristino della posizione dopo due tentativi consecutivi di arrivare in battuta 4 Manovra di emergenza Lamanovradiemergenza...

Page 10: ...della centralina che anche in caso di blackout alimentano i circuiti ad essa collegati Quando la batteria si scarica completamente in assenza di tensione di rete il programmatore perde la posizione de...

Page 11: ...11 NOTES...

Page 12: ...t professionally qualified installers of electricalequipment andmustrespectthelocalstandardsandregula tions in force All materials used must be approved and must suit the environment in which the inst...

Page 13: ...Indicator for the inverting photoelectric cells FI 3 FI S3 Indicator for the stop photoelectric cells FS 3 FS S4 Indicator for the safety edge CP 3 CP S5 Indicator for the opening button TA TA S6 Ind...

Page 14: ...ONTRAST 0 63 REAR LIGHTING ALWAYS ON 60 30 SEC EXIT PROG OK to return to display Note 1 Note 2 Note 3 Note 3 Note 6 Note 7 Note 8 Note 9 The number of manoeuvres carried out by the operator arm and th...

Page 15: ...S CP TA TD TC TAL AUTO PROG TB FI FS CP TA TD TC TAL OPENING TB FI FS CP TA TD TC TAL STOP OPENING TB FI FS CP TA TD TC TAL CLOSING TB FI FS CP TA TD TC TAL STOP CLOSING PROG OK to confirm PRESS the t...

Page 16: ...ng ulterior channels via radio S4XX transmitters The system can be remotely activated using radio control devices with outopeningthereceiver bysetting MEMORADIO hasbeenactivated in the OPTIONS menu 1...

Page 17: ...le by law A MEMORIZZAZIONE CODICE TX TX TXQ504C4 29 10 2013 DM0912 Description Product Code Date Drawing number P J Heath CARDIN ELETTRONICA S p A 31020 San Vendemiano TV Italy via Raffaello 36 Tel 04...

Page 18: ...ning on battery power is dependent on the ambient conditions and on the load connected at binding posts 16 17 power is always routed there during blackouts When the battery is completely flat during b...

Page 19: ...19 NOTES...

Page 20: ...en bon tat En cas de coupure de courant et batteries d charg es le programmateur perd la m morisation de la position occup e par le vantail cette situationentra neunesignalisationd alarmeetunrepositi...

Page 21: ...v criture blanche sur fond noir Branchements du bornier 7 CMN commun pour toutes les entr es sorties 8 ELS sortie pour serrure lectrique 12 Vdc 15 W 9 10 LC CH2 sortie contact non aliment N O pour act...

Page 22: ...63 LUMIERE FONDE TOUJOUR ON 60 30 SEC SORTIE PROG OK pour confirmer CONTRASTE 0 63 LUMIERE FONDE TOUJOUR ON 60 30 SEC SORTIE PROG OK pour changer le valeur CONTRASTE 0 63 LUMIERE FONDE TOUJOUR ON 60 3...

Page 23: ...te ou de gauche pour modifier la langue Italiano Fran ais Appuyer sur la touche PROG OK pour confirmer la langue PROG OK pour confirmer APPUYER sur l metteur le canal m moriser APPUYER sur l metteur l...

Page 24: ...is termin l effacement total de la m moire l afficheur revient la rubrique EFF TOTAL M morisation par radio d autres canaux seulement S4XX Cette m morisation peut galement tre activ e via radio sans d...

Page 25: ...on d action de la t l commande et qui ont au moins un canal de l metteur de m moris enclencheront simultan ment l avertisseur sonore B1 fig 1 2 Pour s lectionner le r cepteur dans lequel il faut m mor...

Page 26: ...tifsbranch sauxbornes16 17 fig 1 de la centrale lesquelles alimentent m me en cas de coupure de courant les circuits y aff rents Quand la batterie se d charge compl tement en cas de coupure de courant...

Page 27: ...27 NOTES...

Page 28: ...eistungsf higkeit der Batterien sollte daher alle sechs Monate berpr ft werden siehe Seite 34 berpr fung der Batterien NachdemdieVorrichtunginstalliertwurdeundbevordieSteuerung mitStromversorgtwird mu...

Page 29: ...TB S2 Anzeige Bewegungsumkehrunglichtschranken FI 3 FI S3 Anzeige Lichtschranke f r Stop FS 3 FS S4 Anzeige Sicherheitsleiste CP 3 CP S5 Anzeige ffnungstaste TA TA S6 Anzeige Schlie ungstaste TC TC S...

Page 30: ...FF PHASENVERSCHIEB ON OFF ELEKTROSCHLOSS ON OFF FUNK SPEICHERUNG ON OFF ELEKTROSCHLOSS ON OFF FUNK SPEICHERUNG ON OFF AUSGANG LC CH2 FUNK KANAL WACHLICHT PROG OK um zu best tigen PROG OK um der Wert z...

Page 31: ...eln Italienisch Deutsch Zur Best tigung der Sprache die Taste PROG OK dr cken PROG OK um zu best tigen Die zu speichernde Kanaltaste auf dem Sender dr cken Die zu speichernde Kanaltaste auf dem Sender...

Page 32: ...zur ck Speicherung weiterer Kan le ber Funk nur S4XX Die Speicherung kann auch ber Funk aktiviert werden ohne die Dose zu ffnen in der sich das Steuerger t befindet wenn die Einstellung FUNKSPEICHERU...

Page 33: ...e Drawing number P J Heath CARDIN ELETTRONICA S p A 31020 San Vendemiano TV Italy via Raffaello 36 Tel 0438 401818 Fax 0438 401831 Draft All rights reserved Unauthorised copying or use of the informat...

Page 34: ...mie des Systems ist bei einer Versorgung durch Batterie eng verbunden mit den Umweltbedingungen und dem an die Klemmen 16 17 Abb 1 der Steuereinheit die auch bei Stromausfall die an sie angeschlossene...

Page 35: ...35 NOTES...

Page 36: ...namiento Controlar tambi n el buen funcionamiento de las bater as cada seis meses v ase p g 42 Prueba de las bater as Tras haber instalado el dispositivo y antes de proporcionar tensi n a la centralit...

Page 37: ...fotoc lulas de parada FS 3 FS S4 Se alizaci n banda sensibile CP 3 CP S5 Se alizaci n tecla de apertura TA TA S6 Se alizaci n tecla de cierre TC TC S7 Se alizaci n control secuencial TD TD S8 Se aliza...

Page 38: ...LULA INV EN CIERRE ADEMAS EN STOP LUZ TESTIGO FIJA INTERMITENTE FOTOCELULA INV EN CIERRE ADEMAS EN STOP TEST FI ON OFF FOTOCELULA INV EN CIERRE ADEMAS EN STOP TEST FI ON OFF TEST FS ON OFF TEST FS ON...

Page 39: ...de funcionamiento TB FI FS CP TA TD TC TAL PAUSA TB FI FS CP TA TD TC TAL AUTO PROG TB FI FS CP TA TD TC TAL APERTURA TB FI FS CP TA TD TC TAL STOP APERTURA TB FI FS CP TA TD TC TAL CIERRE TB FI FS C...

Page 40: ...lo S4XX Lamemorizaci npuedeactivarsetambi nv aradio sinabrirlacajadondela centralita est alojada si la configuraci n MEMO RADIO ha sido activada en el men OPCIONES 1 Utilizando un radiomando en el cua...

Page 41: ...runa delasteclasdecanaldelmismoemisor Losreceptoresquenocontenganel c digodedichateclasedesactivar nconlaemisi ndeun bip de5segundos deduraci n encambio elquecontengaelc digoemitir otro bip quedurar u...

Page 42: ...onectada a los bornes 16 17 fig 1 de la centralita que tambi n en caso de interrupci n total de la energ a alimenta los circuitos conectados con la misma Cuando la bater a se descarga completamente cu...

Page 43: ...x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x...

Page 44: ...quency module aerial connection FM NO inputs opening button limited opening button closing button dynamic button NC 8 2 k inputs inverting photocells stop photocells blocking button safety edge Output...

Reviews: