background image

15

“PROG/OK” 

to return to

 ‘motions’

“PROG/OK” 

to confirm

Press the arrows 

to increase or 

decrease the value 

(max. 63)

* * * * * *  * * * * * * * *  *
*                            *

*   SET CONTRAST   *
*                  SEC.    *
*                            *

* * * * * *  * * * * * * * *  *

26

“PROG/OK” 

to return to

 ‘options’

OPTIONS

SAFETY DEVICES 

MOTION
DISPLAY
REMOTE

PROGRAM

TB FI
FS CP

TA TD

TC TAL

00.000.007
CC2X24    V1.00

OPTIONS

SAFETY DEVICES
MOTION
DISPLAY
REMOTE

Arrow

to scroll

SEQUENTIAL COM.

OPEN-SHUT/

OPEN-STOP-SHUT

AUTO. RECLOSING

ON/OFF

PRE-FLASHING

ON/OFF

OPTIONS
SAFETY DEVICES 

MOTION

DISPLAY
REMOTE

Arrow

to scroll

OPTIONS
SAFETY DEVICES 
MOTION

DISPLAY

REMOTE

Arrow

to scroll

SEQUENTIAL COM.

OPEN-SHUT/

OPEN-STOP-SHUT

AUTO. RECLOSING

ON/OFF

PRE-FLASHING

ON/OFF

SEQUENTIAL COM.

OPEN-SHUT/

OPEN-STOP-SHUT

AUTO. RECLOSING

ON/OFF

PRE-FLASHING

ON/OFF

PRE-FLASHING

ON/OFF

WARNING LIGHTS

FIXED/

INTERMITTENT

INDICATOR LIGHT 

FIXED/

INTERMITTENT

WARNING LIGHTS

FIXED/

INTERMITTENT

INDICATOR LIGHT

FIXED/

INTERMITTENT

PHOTOCELL INVERT

DURING CLOSING/

AND IN STOP 

INDICATOR LIGHT

FIXED/

INTERMITTENT

PHOTOCELL INVERT

DURING CLOSING/

AND IN STOP

TEST FI

ON/OFF

PHOTOCELL INVERT

DURING CLOSING/

AND IN STOP  

TEST FI

ON/OFF

TEST FS 

ON/OFF

TEST FS

ON/OFF

GATE DELAY

DURING OPENING

ON/OFF

ELECTRIC LOCK

ON/OFF

TEST FI

ON/OFF

TEST FS

ON/OFF

GATE DELAY 

DURING OPENING

ON/OFF

GATE DELAY

ON/OFF

ELECTRIC LOCK

ON/OFF

MEMO RADIO

ON/OFF

ELECTRIC LOCK

ON/OFF

REMOTE

ON/OFF

OUTPUT LC/CH2

RADIO CHANNEL/

COURTESY LIGHT

“PROG/OK” 

to confirm

“PROG/OK” 

to change

the value

“PROG/OK” 

to change

the value

“PROG/OK” 

to change

the value

“PROG/OK” 

to change

the value

“PROG/OK” 

to change

the value

“PROG/OK” 

to change

the value

“PROG/OK” 

to change

the value

“PROG/OK” 

to change

the value

“PROG/OK” 

to change

the value

“PROG/OK” 

to change

the value

MEMO RADIO

ON/OFF

OUTPUT LC/CH2

COURTESY LIGHT/

RADIO CHANNEL

EXIT

“PROG/OK” 

to change

the value

CONTACT TB

NC/8K2

CONTACT FI

NC/8K2

CONTACT FS

NC/8K2

                          

CONTACT TB

NC/8K2

CONTACT FI

NC/8K2

CONTACT FS

NC/8K2

“PROG/OK” 

to confirm

“PROG/OK” 

to change

the value

“PROG/OK” 

to change

the value

CONTACT TB

NC/8K2

CONTACT FI

NC/8K2

CONTACT FS

NC/8K2

“PROG/OK” 

to change

the value

CONTACT FI

NC/8K2

CONTACT FS

NC/8K2

CONTACT CP

NC/8K2

“PROG/OK” 

to change

the value

CONTACT FS

NC/8K2

CONTACT CP

NC/8K2

EXIT

“PROG/OK” 

to return to

 ‘safety devices’

MOTOR SELECTION

BL824

CURRENT SENSOR

LEVEL 1...5 

LIMITED OPENING

SETTING 1...5 

                          

MOTOR SELECTION

BL824

CURRENT SENSOR

LEVEL 1...5 

LIMITED OPENING

SETTING 1...4 

 

“PROG/OK” 

to confirm

“PROG/OK” 

to change

the value

MOTOR SELECTION

BL824

CURRENT SENSOR

LEVEL 1...5

LIMITED OPENING

SELECTION 1...4 

“PROG/OK” 

to change

the value

CURRENT SENSOR

LEVEL 1...5 

LIMITED OPENING

SETTING 1...5

DIST. FROM CLOSE

STEPS 1...9

 

 

“PROG/OK” 

to change

the value

“PROG/OK” 

to change

the value

CONTRAST

0....63  

REAR LIGHTING

ALWAYS ON/60/30 SEC.

EXIT

                          

“PROG/OK” 

to confirm

CONTRAST

0....63  

REAR LIGHTING

ALWAYS ON/60/30 SEC.

EXIT

                          

“PROG/OK” 

to change

the value

CONTRAST

0....63  

REAR LIGHTING

ALWAYS ON/60/30 SEC.

EXIT

“PROG/OK” 

to return to

‘display’

Note: 1

Note: 2

Note: 3

Note: 3

Note: 6

Note: 7

Note: 8

Note: 9

The number of 

manoeuvres 

carried out by 

the operator 

arm and the 

ECU model are 

always shown 

on the opening 

screen of the 

display.

The plug 

symbol

indicates that the 

ECU is working 

off mains power.

The fully

charged battery 

symbol

indicates that the 

ECU is working 

off battery power 

at 100%.

75%

50%

25%

0%

Note: 4

Note: 5

ITALIANO

FRANÇAIS

ENGLISH

NEDERLANDS

DEUTSCH

ESPAÑOL

PROGRAM

TB FI
FS CP

TA TD

TC TAL

00.000.007
CC2X24    V1.00

press both arrows 

simultaneously to enter

the language submenu

“PROG/OK” to confirm

Flashing on the display. You have to enter the programming mode to program the system. 

During normal operation it indicates that the "automatic repositioning" procedure is about to 

take place. In this case any commands received (

TA, TC, TAL or TD

) will automatically start 

this procedure.

This happens when an N.C. contact is activated (

FI, FS, CP

) during encoder programming or 

automatic repositioning. Once the passive state of the security devices has been reset the gate 

will start moving again automatically. It also happens if a blackout occurs during programming.

Safety device test error. Check the condition of the safety devices and make sure that the 

alarm cuts in when an obstacle interferes with the beam (indication white characters on a black 

background). In case of anomalies replace the damaged safety device or bridge the contact 

and deactivate the safety test  (option menu).

This occurs when the programmer sends a command to the motor and nothing happens (motor 

1/2

 doesn't move). Check the Faston connections of motor 

1/2

  and the condition of the fuses 

"

F3

", "

F4

" and then give another opening or closing command. If the motor still doesn't move 

you are faced with either a mechanical problem or a problem with the programmer. 

Encoder count error motor 

1/2

 . If this error occurs during normal motor operation it means 

that there is a problem with one of the encoder signals. Check the relative connections and 

carry out automatic repositioning.
Encoder direction error motor 

1/2

 : The gate movement direction is different from the encoder 

setting (eg. the gate moves in the closing direction while the program is carrying out the 

opening stage). Check motor 

1/2

  power supply connections.

Current sensor error motor 

1/2

 . When the gate is not moving this symbol means there is a 

problem with the current sensor 

1/2

 .

Opening this contact will provoke a travel direction inversion during the closing stage and 

during the opening stage.

If the sensor intervenes during the opening direction the gate inverts the travel direction immediately 

and proceeds to the fully open position. If the sensor intervenes during the closing direction the gate 

automatically inverts the travel direction of a few centimetres and then stops to free the obstacle.

   

Alarm indications

TB FI
FS

CP

TA TD

TC

TAL

PROGRAM

TB FI
FS

CP

TA TD

TC

TAL

OUT OF POS

TB FI
FS

CP

TA TD

TC

TAL

SAFETY ERROR

TB FI
FS

CP

TA TD

TC

TAL

STOP PROG

AUTO PROG

TB FI
FS

CP

TA TD

TC

TAL

ERROR MOT1/2

TB FI
FS

CP

TA TD

TC

TAL

ERROR ENC1/2

TB FI
FS

CP

TA TD

TC

TAL

ERROR DIR1/2

TB FI
FS

CP

TA TD

TC

TAL

ERROR SENS1/2

TB FI
FS

CP

TA TD

TC

TAL

ACT. SAFETY EDGE

TB FI
FS

CP

TA TD

TC

TAL

ACTIVE SENSOR

Press an arrow 

key to enter the 

main menu

LIMITED OPENING

SETTING 1...5

DIST. FROM CLOSE

STEPS 1...9 

GATE DELAY

STEPS 0...9

 

DIST. FROM CLOSE

STEPS 1...9 

GATE DELAY

STEPS 0...9 

BRAKING ROOM

SETTING 1...3

BRAKING ROOM

SETTING 1...3

BRAKING SPEED

SETTING 1...3

PAUSE TIME

130 SEC.

BRAKING SPEED

SETTING 1...3

PAUSE TIME

130 SEC.

EXIT

“PROG/OK” 

to confirm

Press the arrows to increase or 

decrease the value (max. 240 sec).

Keeping the arrows held down will 

force the value to scroll rapidly.

* * * * * *  * * * * * * * *  *
*                            *

*       

PAUSE TIME

      *

*                 

SEC.

     *

*                            *

* * * * * *  * * * * * * * *  *

180

GATE DELAY

STEPS 0...9 

BRAKING ROOM

SETTING 1...3

BRAKING SPEED

SETTING 1...3

“PROG/OK” 

to change

the value

Note: 10

“PROG/OK” 

to change

the value

Note: 11

“PROG/OK” 

to change

the value

Note: 12

Language choice:

•  Press the right and left buttons simultaneously to enter the language submenu.
•  Press the right and left buttons to change the language: Italian to English.
•  Press the "PROG/OK" button to confirm the choice.

Pause time programming or pause for 

automatic reclosing (if activated)

Automatic programming under way

Opening stage

Block during opening   

Closing stage

Block during closing 

 

Operational indications

TB FI
FS

CP

TA TD

TC

TAL

PAUSE

TB FI
FS

CP

TA TD

TC

TAL

AUTO PROG

TB FI
FS

CP

TA TD

TC

TAL

OPENING

TB FI
FS

CP

TA TD

TC

TAL

STOP OPENING

TB FI
FS

CP

TA TD

TC

TAL

CLOSING

TB FI
FS

CP

TA TD

TC

TAL

  STOP CLOSING

“PROG/OK” 

to confirm

PRESS the

transmitter

channel

to memorise

PRESS the

the same 

transmitter

channel

again

“PROG/OK” 

to confirm

Arrow

to scroll

ENCODING: S4XX  

MEMORISE

CANCEL

CLEAR ALL MEMORY
CHANNEL FUNCTION

EXIT

“PROG/OK” 

to confirm

OPTIONS

SAFETY DEVICES 

MOTION
DISPLAY

CALENDAR

REMOTE

MEMORISE

[Nr...]

* * * * * *  * * * * * * * *  *
*                           *

*  ACTIVATION 1    *

*                           *

* * * * * *  * * * * * * * *  *

MEMORISE

[Nr...]

* * * * * *  * * * * * * * *  *
*                           *

*  ACTIVATION 2    *

*                           *

* * * * * *  * * * * * * * *  *

MEMORISE

[Nr...]

* * * * * *  * * * * * * * *  *
*                           *

*       CODE           *
*  MEMORISED     *

* * * * * *  * * * * * * * *  *

“PROG/OK” 

to confirm

CANCEL

[Nr...]

* * * * * *  * * * * * * * *  *
*                           *

*  ACTIVATION 1    *

*                           *

* * * * * *  * * * * * * * *  *

PRESS the

transmitter

channel

to memorise

CANCEL

[Nr...]

* * * * * *  * * * * * * * *  *
*                           *

*  ACTIVATION 2    *

*                           *

* * * * * *  * * * * * * * *  *

PRESS the

the same 

transmitter

channel

again

CANCEL

[Nr...]

* * * * * *  * * * * * * * *  *
*                           *

*       CODE           *
*   CANCELLED    *

* * * * * *  * * * * * * * *  *

ENCODING: S4XX  

MEMORISE

CANCEL

CLEAR ALL MEMORY
CHANNEL FUNCTION

EXIT

“PROG/OK” 

to confirm

* * * * * *  * * * * * * * *  *
*       CANCEL         *

*  ALL MEMORY ?  *

* * * * * *  * * * * * * * *  *

PRESS ok to  

cancel all 

memory

or press exit

ENCODING: S4XX  

MEMORISE

CANCEL

CLEAR ALL MEMORY

CHANNEL FUNCTION

EXIT

Arrow

to exit

EXIT

OK

* * * * * *  * * * * * * * *  *
*   CANCELLING    *

* * * * * *  * * * * * * * *  *

ENCODING: S4XX  

MEMORISE

CANCEL

CLEAR ALL MEMORY

CHANNEL FUNCTION

EXIT

CHANNEL A

channel function A

CHANNEL

 

B

channel function B

CHANNEL C

channel function C

CHANNEL D

channel function D

EXIT

ENCODING: S4XX  

MEMORISE

CANCEL

CLEAR ALL MEMORY
CHANNEL FUNCTION

EXIT

“PROG/OK” 

to change

the value

ENCODING: S4XX  

MEMORISE

CANCEL

CLEAR ALL MEMORY
CHANNEL FUNCTION

EXIT

“PROG/OK” 

to toggle the 

value  between

S4XX & S500

“PROG/OK” 

to return to

the remote

menu

[AB--]

[AB--]

[AB--]

[AB--]

[AB--]

[AB--]

Note: 14

Note: 13

•  Set the main operating parameters (e.g. the presence of an electric lock ON/OFF) in the options menu.

•  If you have safety devices working with 8.2k contacts select the correct setting from the  safety device menu.

•  Before programming the gate travel distances select the correct motor in the "Motion" menu.

Notes

7) 

Current sensor settings:

Level 1

 = motor electrical input + 

1

 

amp

Level 2

 = motor electrical input + 

2

 

amps

Level 3

 = motor electrical input  + 

3

 

amps

 

The programmer checks the electrical input to the motor, detecting any 

eventual increase in effort above the normal operating limits and intervenes 

as an additional safety device. 

8) 

Limited opening

 

Select from 1 to 4:  

 

Selection 1 = 1/3 travel distance Gate 1 

 

Selection 2 = 1/2 travel distance Gate 1 

 

Selection 3 = 2/3 travel distance Gate 1

 

Selection 4 = entire travel distance Gate 1

9) 

Setting the distance from the opening travel limit:

 

To increase or reduce this distance modify the parameter in steps from 0 

to 9. By default the appliance is set to level 4 and in this way the gate will 

not slam against the travel limit but will stop within a centimetre of it.

10) 

Gate delay

 

To increase or reduce this distance modify the parameter in steps from 

0 to 9.  Setting the gate delay between the two gate leaves in opening and 

consequently in closing.

 11)  

Braking room

 

To increase or reduce this distance modify the parameter in steps from 

0 to 3. Setting the braking room towards the end of the closing stage. The 

default paramter is '0', i.e, disabled.

12)  

Braking speed

 

To increase or reduce this speed modify the parameter in steps from 0 to 

9.  Setting the braking speed during closing. The default paramter is '1' but 

it only tales effect if paramter   11 "braking room" is set to 1, 2 or 3.

13)  

Encoding

 

Before changing the encoding type you must substitute the memory module, 

changing from  S4XX to S500 and viceversa, with the power switched off. 

14)  

Channel functions

 

Each radio control channel can be

 "

A

","

B

","

C

","

D

" set to one of 7 available functions: 

TD

 sequential command - 

TAL

 limited opening   

-

 TA

 open - 

TC

 close 

Block

 - 

CH2

 second radio channel - 

No command

Summary of Contents for CC242ETOP

Page 1: ...lectrique exemple d installation Page 3 Consignes importantes Page 20 Branchement lectrique Pages 20 21 Proc d de programmation Page 22 23 Menu de visualisation Page 24 Commande via radio Page 24 25 M...

Page 2: ...pliqu e sur l emballage ou sur la notice d installation et d utilisation fournie avec le produit mettez le programmateur lectronique hors tension remplacez le module de m moire 24 LC16 S449 par le mod...

Page 3: ...RL 24Vdc CMN LS LP CMN LC CH2 ELS 12Vdc CMN F4 10 A J3 F3 10 A BATTERY CHARGER J1 R1 J6 J2 J4 L2 ANS400 Enable Disable ANQ800 1 3 4 5 6 1 2 Bl Gr Gy Yw M1 ENCODER 1 Rd Bk M1 3 4 5 6 1 2 Bl Gr Gy Yw M2...

Page 4: ...o scariche si verifica laperditadelcontrollodellaposizionedell antaconconseguente segnalazionediallarmeenecessit diriposizionamento Controllare quindi l efficienza delle batterie ogni sei mesi vedi pa...

Page 5: ...gnalazione fotocellule di stop FS 3 FS S4 Segnalazione costa sensibile CP 3 CP S5 Segnalazione tasto di apertura TA TA S6 Segnalazione tasto di chiusura TC TC S7 Segnalazione comando sequenziale TD TD...

Page 6: ...IN STOP TEST FI ON OFF TEST FS ON OFF TEST FS ON OFF SFASAM APERTURA ON OFF ELETTROSERRATURA ON OFF TEST FI ON OFF TEST FS ON OFF SFASAMENTO IN APERTURA ON OFF SFASAM APERTURA ON OFF ELETTROSERRATURA...

Page 7: ...TAL INT COSTA TB FI FS CP TA TD TC TAL INT SENS PROG OK per confermare PREMERE sul trasmettitore il canale da memorizzare PREMERE sul trasmettitore lo stesso canale per memorizzare PROG OK per conferm...

Page 8: ...alla voce CANCEL TOTALE Memorizzazione di ulteriori canali via radio solo S449 S486 La memorizzazione pu essere anche attivata via radio senza aprire la scatola dove alloggiata la centralina se l imp...

Page 9: ...essere spostate a mano una volta ribloc cati il programmatore provveder al ripristino della posizione dopo due tentativi consecutivi di arrivare in battuta 4 Manovra di emergenza Lamanovradiemergenza...

Page 10: ...della centralina che anche in caso di blackout alimentano i circuiti ad essa collegati Quando la batteria si scarica completamente in assenza di tensione di rete il programmatore perde la posizione de...

Page 11: ...11 NOTES...

Page 12: ...t professionally qualified installers of electricalequipment andmustrespectthelocalstandardsandregula tions in force All materials used must be approved and must suit the environment in which the inst...

Page 13: ...Indicator for the inverting photoelectric cells FI 3 FI S3 Indicator for the stop photoelectric cells FS 3 FS S4 Indicator for the safety edge CP 3 CP S5 Indicator for the opening button TA TA S6 Ind...

Page 14: ...ONTRAST 0 63 REAR LIGHTING ALWAYS ON 60 30 SEC EXIT PROG OK to return to display Note 1 Note 2 Note 3 Note 3 Note 6 Note 7 Note 8 Note 9 The number of manoeuvres carried out by the operator arm and th...

Page 15: ...S CP TA TD TC TAL AUTO PROG TB FI FS CP TA TD TC TAL OPENING TB FI FS CP TA TD TC TAL STOP OPENING TB FI FS CP TA TD TC TAL CLOSING TB FI FS CP TA TD TC TAL STOP CLOSING PROG OK to confirm PRESS the t...

Page 16: ...ng ulterior channels via radio S4XX transmitters The system can be remotely activated using radio control devices with outopeningthereceiver bysetting MEMORADIO hasbeenactivated in the OPTIONS menu 1...

Page 17: ...le by law A MEMORIZZAZIONE CODICE TX TX TXQ504C4 29 10 2013 DM0912 Description Product Code Date Drawing number P J Heath CARDIN ELETTRONICA S p A 31020 San Vendemiano TV Italy via Raffaello 36 Tel 04...

Page 18: ...ning on battery power is dependent on the ambient conditions and on the load connected at binding posts 16 17 power is always routed there during blackouts When the battery is completely flat during b...

Page 19: ...19 NOTES...

Page 20: ...en bon tat En cas de coupure de courant et batteries d charg es le programmateur perd la m morisation de la position occup e par le vantail cette situationentra neunesignalisationd alarmeetunrepositi...

Page 21: ...v criture blanche sur fond noir Branchements du bornier 7 CMN commun pour toutes les entr es sorties 8 ELS sortie pour serrure lectrique 12 Vdc 15 W 9 10 LC CH2 sortie contact non aliment N O pour act...

Page 22: ...63 LUMIERE FONDE TOUJOUR ON 60 30 SEC SORTIE PROG OK pour confirmer CONTRASTE 0 63 LUMIERE FONDE TOUJOUR ON 60 30 SEC SORTIE PROG OK pour changer le valeur CONTRASTE 0 63 LUMIERE FONDE TOUJOUR ON 60 3...

Page 23: ...te ou de gauche pour modifier la langue Italiano Fran ais Appuyer sur la touche PROG OK pour confirmer la langue PROG OK pour confirmer APPUYER sur l metteur le canal m moriser APPUYER sur l metteur l...

Page 24: ...is termin l effacement total de la m moire l afficheur revient la rubrique EFF TOTAL M morisation par radio d autres canaux seulement S4XX Cette m morisation peut galement tre activ e via radio sans d...

Page 25: ...on d action de la t l commande et qui ont au moins un canal de l metteur de m moris enclencheront simultan ment l avertisseur sonore B1 fig 1 2 Pour s lectionner le r cepteur dans lequel il faut m mor...

Page 26: ...tifsbranch sauxbornes16 17 fig 1 de la centrale lesquelles alimentent m me en cas de coupure de courant les circuits y aff rents Quand la batterie se d charge compl tement en cas de coupure de courant...

Page 27: ...27 NOTES...

Page 28: ...eistungsf higkeit der Batterien sollte daher alle sechs Monate berpr ft werden siehe Seite 34 berpr fung der Batterien NachdemdieVorrichtunginstalliertwurdeundbevordieSteuerung mitStromversorgtwird mu...

Page 29: ...TB S2 Anzeige Bewegungsumkehrunglichtschranken FI 3 FI S3 Anzeige Lichtschranke f r Stop FS 3 FS S4 Anzeige Sicherheitsleiste CP 3 CP S5 Anzeige ffnungstaste TA TA S6 Anzeige Schlie ungstaste TC TC S...

Page 30: ...FF PHASENVERSCHIEB ON OFF ELEKTROSCHLOSS ON OFF FUNK SPEICHERUNG ON OFF ELEKTROSCHLOSS ON OFF FUNK SPEICHERUNG ON OFF AUSGANG LC CH2 FUNK KANAL WACHLICHT PROG OK um zu best tigen PROG OK um der Wert z...

Page 31: ...eln Italienisch Deutsch Zur Best tigung der Sprache die Taste PROG OK dr cken PROG OK um zu best tigen Die zu speichernde Kanaltaste auf dem Sender dr cken Die zu speichernde Kanaltaste auf dem Sender...

Page 32: ...zur ck Speicherung weiterer Kan le ber Funk nur S4XX Die Speicherung kann auch ber Funk aktiviert werden ohne die Dose zu ffnen in der sich das Steuerger t befindet wenn die Einstellung FUNKSPEICHERU...

Page 33: ...e Drawing number P J Heath CARDIN ELETTRONICA S p A 31020 San Vendemiano TV Italy via Raffaello 36 Tel 0438 401818 Fax 0438 401831 Draft All rights reserved Unauthorised copying or use of the informat...

Page 34: ...mie des Systems ist bei einer Versorgung durch Batterie eng verbunden mit den Umweltbedingungen und dem an die Klemmen 16 17 Abb 1 der Steuereinheit die auch bei Stromausfall die an sie angeschlossene...

Page 35: ...35 NOTES...

Page 36: ...namiento Controlar tambi n el buen funcionamiento de las bater as cada seis meses v ase p g 42 Prueba de las bater as Tras haber instalado el dispositivo y antes de proporcionar tensi n a la centralit...

Page 37: ...fotoc lulas de parada FS 3 FS S4 Se alizaci n banda sensibile CP 3 CP S5 Se alizaci n tecla de apertura TA TA S6 Se alizaci n tecla de cierre TC TC S7 Se alizaci n control secuencial TD TD S8 Se aliza...

Page 38: ...LULA INV EN CIERRE ADEMAS EN STOP LUZ TESTIGO FIJA INTERMITENTE FOTOCELULA INV EN CIERRE ADEMAS EN STOP TEST FI ON OFF FOTOCELULA INV EN CIERRE ADEMAS EN STOP TEST FI ON OFF TEST FS ON OFF TEST FS ON...

Page 39: ...de funcionamiento TB FI FS CP TA TD TC TAL PAUSA TB FI FS CP TA TD TC TAL AUTO PROG TB FI FS CP TA TD TC TAL APERTURA TB FI FS CP TA TD TC TAL STOP APERTURA TB FI FS CP TA TD TC TAL CIERRE TB FI FS C...

Page 40: ...lo S4XX Lamemorizaci npuedeactivarsetambi nv aradio sinabrirlacajadondela centralita est alojada si la configuraci n MEMO RADIO ha sido activada en el men OPCIONES 1 Utilizando un radiomando en el cua...

Page 41: ...runa delasteclasdecanaldelmismoemisor Losreceptoresquenocontenganel c digodedichateclasedesactivar nconlaemisi ndeun bip de5segundos deduraci n encambio elquecontengaelc digoemitir otro bip quedurar u...

Page 42: ...onectada a los bornes 16 17 fig 1 de la centralita que tambi n en caso de interrupci n total de la energ a alimenta los circuitos conectados con la misma Cuando la bater a se descarga completamente cu...

Page 43: ...x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x...

Page 44: ...quency module aerial connection FM NO inputs opening button limited opening button closing button dynamic button NC 8 2 k inputs inverting photocells stop photocells blocking button safety edge Output...