Chapter 16
16-9
16.4 Alarm Code
16.4.1 Alarm Code (ADF)
0020-9550
T-16-8
16.5 Fax Error Codes
16.5.1 Outline
16.5.1.1 Error Code Outline
0020-4435
An error code is used to indicate a fault in a machine, and is indicated in the machine's LCD or reports, showing the nature (symptoms) of the fault. Using the error
code, the user or the service man can readily find out how to correct the fault by simply referring to the User's Manual or service manual.
An error code may be either of the following two types:
- User Error Codes
A fault indicated as a user error code is one that can easily be corrected by the user, as by operating the machine. It takes the form of "#+number."
-
Service Error Codes
If a fault calls for a service man for correction, it is indicated as a service man error code in the form of "##+number" or "SYSTEM ERROR E+number."
16.5.2 User Error Code
16.5.2.1 User Error Code
0020-4437
T-16-9
16.5.3 Service Error Code
16.5.3.1 Service Error Code
0020-4439
T-16-10
Code Name Sensor
No.
Description
0003H
Separation NG alarm
SR719
The leading edge of paper does not reach the ADF paper trailing edge sensor (SR719) within
3.2 sec after the ADF pickup motor starts positive rotation.
MEMO:
-
A service error code expressed in the form of "##+number" will not appear on the LCD, Error Tx Report, or Activity Report while the machine remains in factory
default state. To check a service error code, shift bit 0 of service soft switch #1 SSSW SW01 to '1'.
-
Display only the error codes which are newly incorporated in this machine as well as which require remedies unique to the product. For the causes and
countermeasures of other error codes, refer to the separate G3/G4 Facsimile Error Code List (Rev. 2).
No.
Tx/Rx
Description
#0001
[Tx]
an original has jammed.
#0003
[Tx]
tine-out for copying or sending/receiving a single page has occurred.
#0005
[Tx]
time-out for initial identification (T0/T1) has occurred.
#0012
[Rx]
recording paper is absent at the other party.
#0018
[Tx]
auto call initiation has failed.
#0037
[Rx]
image memory overflow at time of reception has occurred.
No. Tx/Rx
Description
##0100
[Tx]
at time of transmission, the procedural signal has been transmitted more than specified.
##0101
[Tx]
the modem speed does not match that of the other party.
##0102
[Tx]
at time of transmission, fall-back cannot be used.
##0104
[Tx]
at time of transmission, RTN or PIN is received.
##0106
[Rx]
at time of reception, the procedural signal is received for 6 sec while in wait for the signal.
##0107
[Rx]
at time of reception, the transmitting party cannot use fall-back.
##0109
[Tx]
at time of transmission, a signal other than DIS, DTC, FTT, CFR, or CRP is received, and the procedural signal has been sent
more than specified.
##0114
[Rx]
at time of reception, RTN is transmitted.
##0200
[Rx]
at time of reception, no image carrier is detected for 5 sec.
##0201
[Tx]
DCN is received outside the normal parity procedure.
##0224
[Tx]
Error has occurred on transmission procedural signal.
##0228
[Rx]
Error has occurred on images' information control.
##0232
[Tx]
encoding error has occurred.
##0237
[Rx]
decoding error has occurred.
##0261
[Tx]
system error has occurred.
##0282
[Tx]
at time of transmission, the procedural signal has been transmitted more than specified.
##0283
[Tx]
at time of transmission, the procedural signal has been transmitted more than specified.
##0288
[Tx]
after transmission of EOP, a signal other than PIN, PIP, MCF, RTP, or RTN has been received.
##0289
[Tx]
after transmission of EOM, a signal other than PIN, PIP, MCF, RTP, or RTN has been received.
##0290
[Tx]
after transmission of MPS, a signal other than PIN, PIP, MCF, RTP, or RTN has been received.
Summary of Contents for iR C1020 Series
Page 1: ...Sep 8 2008 Service Manual iR C1020 Series iR C1021i ...
Page 2: ......
Page 6: ......
Page 18: ...Contents ...
Page 19: ...Chapter 1 Introduction ...
Page 20: ......
Page 22: ......
Page 57: ...Chapter 2 Installation ...
Page 58: ......
Page 60: ......
Page 73: ...Chapter 3 Basic Operation ...
Page 74: ......
Page 76: ......
Page 81: ...Chapter 4 Main Controller ...
Page 82: ......
Page 84: ......
Page 97: ...Chapter 5 Original Exposure System ...
Page 98: ......
Page 100: ......
Page 112: ......
Page 113: ...Chapter 6 Original Feeding System ...
Page 114: ......
Page 116: ......
Page 132: ......
Page 133: ...Chapter 7 Laser Exposure ...
Page 134: ......
Page 136: ......
Page 143: ...Chapter 8 Image Formation ...
Page 144: ......
Page 146: ......
Page 180: ......
Page 181: ...Chapter 9 Pickup and Feed System ...
Page 182: ......
Page 213: ...Chapter 9 9 29 F 9 79 1 2 3 ...
Page 214: ......
Page 215: ...Chapter 10 Fixing System ...
Page 216: ......
Page 218: ......
Page 233: ...Chapter 11 External and Controls ...
Page 234: ......
Page 263: ...Chapter 12 e maintenance imageWARE Remote ...
Page 264: ......
Page 266: ......
Page 275: ...Chapter 12 12 9 F 12 27 ...
Page 280: ......
Page 281: ...Chapter 13 Maintenance and Inspection ...
Page 282: ......
Page 284: ......
Page 286: ......
Page 287: ...Chapter 14 Measurement and Adjustments ...
Page 288: ......
Page 290: ......
Page 293: ...Chapter 15 Correcting Faulty Images ...
Page 294: ......
Page 296: ......
Page 317: ...Chapter 16 Error Code ...
Page 318: ......
Page 320: ......
Page 331: ...Chapter 16 16 11 ...
Page 332: ......
Page 333: ...Chapter 17 Special Management Mode ...
Page 334: ......
Page 336: ......
Page 343: ...Chapter 17 17 7 ...
Page 344: ......
Page 345: ...Chapter 18 Service Mode ...
Page 346: ......
Page 348: ......
Page 388: ......
Page 389: ...Chapter 19 Upgrading ...
Page 390: ......
Page 392: ......
Page 396: ...Chapter 19 19 4 3 Click Next F 19 4 4 Select a USB connected device and click Next F 19 5 ...
Page 397: ...Chapter 19 19 5 5 Click Start F 19 6 6 Click Yes F 19 7 Download will be started F 19 8 ...
Page 399: ...Chapter 19 19 7 ...
Page 400: ......
Page 401: ...Chapter 20 Service Tools ...
Page 402: ......
Page 404: ......
Page 407: ...Sep 8 2008 ...
Page 408: ......