Chapter 16
16-7
T-16-5
Code
Description
Action
E202
Reader HP sensor fault
0001 Reader HP outward fault
The CCD unit moves backward, but does not move to the home position.
- Replace reader HP sensor.
- Replace reader motor sensor.
- Replace reader unit.
0002 Reader HP homeward fault
The CCD unit moves forward, but does not move to the home position.
- Replace reader HP sensor.
- Replace reader motor sensor.
- Replace reader unit.
E225
Error in light intensity of the lamp
0000 Decrease of light intensity of the lamp.
Replace reader unit.
E248
EEPROM access error
0001 Error at EEPROM power-on
EEPROM data cannot be read at power-on.
Replace reader unit.
0002 Error in EEPROM writing
EEPROM writing cannot be performed.
Replace reader unit.
0003 Error in EEPROM reading after writing
EEPROM reading cannot be performed after writing is performed.
Replace reader unit.
0004 Error in EEPROM register writing
EEPROM register writing cannot be performed.
Replace reader unit.
E351
Main controller PCB fault
0000 Description
Internal error of the main controller PCB
Cause
Main controller PCB fault.
Replace main controller PCB.
E719
Communication error of options
0000 Erroneous communication with card reader (serial communication)
- Disconnection from the card reader has been detected since communication started
after confirmation of normal connection to the card reader (after power-on).
- A serial communication error has occurred. (The serial communication error cannot
be recovered.)
- Check the connectors of the card reader and image processor
PCB.
- Replace the card reader for normal connection.
- Replace the image processor PCB.
0002 Erroneous communication with coin vendor (serial communication)
- Disconnection from the coin vendor has been detected since communication started
after confirmation of normal connection to the coin vendor (after power-on).
- A serial communication error has occurred. (The serial communication error cannot
be recovered.)
- Check the connection between the image processor PCB and
serial PCB.
- Check the connectors of the serial PCB and coin vendor for
normal connection.
- Replace the serial PCB.
- Check the coin vendor.
- Replace the image processor PCB.
E744
Language file/boot ROM/USB memory error
0001 Language file version error
The language file version does not match Bootable.
Download a language file of the correct version.
0002 Language file size error
The language file is longer than the permitted size.
Download a language file of the correct version.
0003 Language file version error
The language file version does not match Bootable.
Download a language file of the correct version.
0004 Language file read error
Reading of language file is invalid.
Download a language file of the correct version.
E804
Error in power supply fan
0000 Description
The fan lock detection signal is input for about 10 sec or longer continuously.
Cause
Power supply fault, DC controller PCB fault.
- Replace the power supply fan
- Replace the DC controller PCB
E805
Error in duplexing fan/CPU fan
0005 Description
The duplexing fan lock detection signal is input for about 10 sec or longer
continuously.
Cause
Duplexing fan fault, DC controller PCB fault.
- Replace the duplexing fan
- Replace the DC controller PCB
E840
Error in pressure release mechanism
0000 Description
Although passing 2.5 sec from the start of HP control, HP (pressure condition) cannot
be controlled.
Cause
Fixing drive assembly fault, fixing pressure release cam fault.
- Replace the fixing drive assembly
- Replace the fixing pressure release cam
Summary of Contents for iR C1020 Series
Page 1: ...Sep 8 2008 Service Manual iR C1020 Series iR C1021i ...
Page 2: ......
Page 6: ......
Page 18: ...Contents ...
Page 19: ...Chapter 1 Introduction ...
Page 20: ......
Page 22: ......
Page 57: ...Chapter 2 Installation ...
Page 58: ......
Page 60: ......
Page 73: ...Chapter 3 Basic Operation ...
Page 74: ......
Page 76: ......
Page 81: ...Chapter 4 Main Controller ...
Page 82: ......
Page 84: ......
Page 97: ...Chapter 5 Original Exposure System ...
Page 98: ......
Page 100: ......
Page 112: ......
Page 113: ...Chapter 6 Original Feeding System ...
Page 114: ......
Page 116: ......
Page 132: ......
Page 133: ...Chapter 7 Laser Exposure ...
Page 134: ......
Page 136: ......
Page 143: ...Chapter 8 Image Formation ...
Page 144: ......
Page 146: ......
Page 180: ......
Page 181: ...Chapter 9 Pickup and Feed System ...
Page 182: ......
Page 213: ...Chapter 9 9 29 F 9 79 1 2 3 ...
Page 214: ......
Page 215: ...Chapter 10 Fixing System ...
Page 216: ......
Page 218: ......
Page 233: ...Chapter 11 External and Controls ...
Page 234: ......
Page 263: ...Chapter 12 e maintenance imageWARE Remote ...
Page 264: ......
Page 266: ......
Page 275: ...Chapter 12 12 9 F 12 27 ...
Page 280: ......
Page 281: ...Chapter 13 Maintenance and Inspection ...
Page 282: ......
Page 284: ......
Page 286: ......
Page 287: ...Chapter 14 Measurement and Adjustments ...
Page 288: ......
Page 290: ......
Page 293: ...Chapter 15 Correcting Faulty Images ...
Page 294: ......
Page 296: ......
Page 317: ...Chapter 16 Error Code ...
Page 318: ......
Page 320: ......
Page 331: ...Chapter 16 16 11 ...
Page 332: ......
Page 333: ...Chapter 17 Special Management Mode ...
Page 334: ......
Page 336: ......
Page 343: ...Chapter 17 17 7 ...
Page 344: ......
Page 345: ...Chapter 18 Service Mode ...
Page 346: ......
Page 348: ......
Page 388: ......
Page 389: ...Chapter 19 Upgrading ...
Page 390: ......
Page 392: ......
Page 396: ...Chapter 19 19 4 3 Click Next F 19 4 4 Select a USB connected device and click Next F 19 5 ...
Page 397: ...Chapter 19 19 5 5 Click Start F 19 6 6 Click Yes F 19 7 Download will be started F 19 8 ...
Page 399: ...Chapter 19 19 7 ...
Page 400: ......
Page 401: ...Chapter 20 Service Tools ...
Page 402: ......
Page 404: ......
Page 407: ...Sep 8 2008 ...
Page 408: ......