15.2. HEATPUMP INSTALLATION
Note:
If a heat pump is connected to the Caddy, the electrical element must be installed to ensure an auxiliary heat
source. (PA01005-15kW, PA01055-18kW, PA01105-20kW)
Heat pump mode operates in "Furnace Only" mode only.
It is possible to connect a heat pump to the Caddy furnace. With a heat pump, the heating source priority menu is
inaccessible. Since the heat pump is the most efficient system to date, it becomes the priority heating source. An
external temperature sensor or a switch connected to the OT input becomes necessary to stop the operation of the
latter in very cold weather. When the heat pump is in defrost mode, the heat pump icon changes to indicate that the
electrical element is operating at the same time as the heat pump.
The same icon is used when a thermostat with 2 heating stages is connected and the electric unit is activated at the
same time as the heat pump. A thermostat with auxiliary or emergency mode is recommended to deactivate the heat
pump in cold weather without having to use a temperature sensor or switch on the furnace.
When the system is configured in heat pump mode, press the wood heating icon to switch the furnace to wood heating
mode. When the heating demand can no longer be answered by the wood, the furnace will automatically return to heat
pump mode.
The defrost signal must be connected to input E of the green connector so that the electrical element activates during
defrost cycles.
For installation of heatpump coil, refer to Section INSTALLATION OF AN AIR CONDITIONING UNIT.
Summary of Contents for PF01015
Page 10: ...10 ADD ON WOOD ONLY WOOD ELECTRIC WOOD OIL ...
Page 13: ...13 INSTALLATION AND OPERATION INSTRUCTIONS CADDY ADD ON SERIAL INSTALLATION PF01015 ...
Page 16: ...16 Option 3 Option 4 ...
Page 17: ...17 EXAMPLE 1 EXAMPLE 2 ...
Page 63: ...63 20 GENERAL ELECTRICAL DIAGRAM STANDALONE FURNACE ...
Page 64: ...64 21 ELECTRICAL DIAGRAM FOR PARALLEL FURNACE ...
Page 65: ...65 22 ELECTRICAL DIAGRAM FOR ELECTRIC UNIT ...
Page 78: ...78 31 ELECTRICAL DIAGRAM BECKETT OIL UNIT ...
Page 79: ...79 32 ELECTRICAL DIAGRAM RIELLO OIL UNIT ...
Page 81: ...81 33 4 AIR CONDITIONNING DAMPER 33 5 HUMIDIFIER 33 6 HEAT PUMP ...
Page 82: ...82 34 EXPLODED VIEW AND PART LIST ...
Page 83: ...83 ...
Page 84: ...84 ...
Page 85: ...85 ...
Page 86: ...86 ...
Page 87: ...87 ...
Page 88: ...88 ...
Page 89: ...89 ...