16.4.3. AUXILIARY HEAT SOURCE PRIORITIZATION
If you have configured one or many auxiliary heating sources (electrical element, heat pump, oil), you must choose the
priority order when there is a heating demand. If, for example, the wood no longer provides sufficient heat, the auxiliary
heating selected in priority one will take over. If priority one no longer provides enough heat, or does not provide it fast
enough, priority 2 will take over. Heating priorities are chosen in the "MAIN" menu, under the "SETUP" option. Select
"OPTIONS" and "CONFIGURATION". Use the arrows to select the priority order.
16.4.4. EXTERNAL TEMPERATURE PROBE
It is possible to connect an external temperature probe on the Caddy. This temperature probe is used primarily to
reduce electricity consumption and reduce the bill by prioritizing the transition to an auxiliary heating source when it is
too cold outside or when it is the overcharging billing period (peak usage) depending on the electricity supplier.
HEAT PUMP:
With a combination wood, electrical component and heat pump you can set your temperature probe to
not use your heat pump when it is too cold and the coefficient of performance becomes too low. (Electrical element
should be prioritized during configuration the outdoor temperature probe.)
When the temperature probe is functioning, the « ECO » mode will show on the main page.
16.5. DISTRIBUTION BLOWER SPEED CONFIGURATION
It is possible to adjust the speed of the distribution blower for circulation mode, air conditioning and any other mode of
auxiliary heaters.
NOTE:
When heating with wood, the fan distribution speeds are programmed in order to provide the best thermal
exchange and cannot be changed.
It is possible to adjust the blower speed in “CIRCULATION” mode at any time by going in the main menu under
“CONFIGURATION” and “BLOWER SPEED”.
The blower speed adjustments for auxiliary heating are available only if the option was activated. The selected speed
in this menu will be the speeds used in the "CIRC", "COOL" and "HEAT" mode.
The adjustment of all controls must be done by a qualified technician. The controls settings and the blower speed must
conform to the recommendations of the CMMTQ.
Summary of Contents for PF01015
Page 10: ...10 ADD ON WOOD ONLY WOOD ELECTRIC WOOD OIL ...
Page 13: ...13 INSTALLATION AND OPERATION INSTRUCTIONS CADDY ADD ON SERIAL INSTALLATION PF01015 ...
Page 16: ...16 Option 3 Option 4 ...
Page 17: ...17 EXAMPLE 1 EXAMPLE 2 ...
Page 63: ...63 20 GENERAL ELECTRICAL DIAGRAM STANDALONE FURNACE ...
Page 64: ...64 21 ELECTRICAL DIAGRAM FOR PARALLEL FURNACE ...
Page 65: ...65 22 ELECTRICAL DIAGRAM FOR ELECTRIC UNIT ...
Page 78: ...78 31 ELECTRICAL DIAGRAM BECKETT OIL UNIT ...
Page 79: ...79 32 ELECTRICAL DIAGRAM RIELLO OIL UNIT ...
Page 81: ...81 33 4 AIR CONDITIONNING DAMPER 33 5 HUMIDIFIER 33 6 HEAT PUMP ...
Page 82: ...82 34 EXPLODED VIEW AND PART LIST ...
Page 83: ...83 ...
Page 84: ...84 ...
Page 85: ...85 ...
Page 86: ...86 ...
Page 87: ...87 ...
Page 88: ...88 ...
Page 89: ...89 ...