Mandatory thermostat connexions to connect a heat pump
Single stage thermostat:
Rh / Rc: No jumper required, already connected on the board
C: Common
Y: Activate the heat pump compressor
G: Activate the blower (In circulation mode)
O: Activate the reversing valve to cool
2
nd
stage connexion or Aux or E (when available)
W: Activate the electrical unit
16. CONFIGURATION AND OPERATING INSTRUCTIONS
16.1. CONTROLS SYSTEM
The Caddy has a sophisticated electronic control. This system is more versatile. All connections are made from the
control panel. Terminal blocks are provided for all components and options.
Before you configure your system and learn how to operate it, make sure that your wall thermostat is wired correctly to
your furnace, that the temperature probe (RTD) is well installed in the hot air plenum and connected to the link board
and that your air distribution system is complete.
The furnace uses a touch screen, the latest technology in control devices. Blowers and power supplies are controlled
from this screen.
It is important to note that your furnace is equipped with three main electronic components: the link board, the power
board and the touch screen. The power board is already installed on the furnace.
The power board is used to supply current to the different electrical components, in particular:
-
Supply current to the different electronic boards;
-
Supply current to the distribution fan;
-
Supply current to the sequencers of the electrical unit (optional);
-
Supply current to the oil burner.
The link board is used more precisely for:
-
Connecting the hot air plenum’s temperature probe (RTD type);
-
Connecting the wall thermostat;
-
Connecting complementary equipments;
-
Connecting a heat pump.
The LCD touch screen is used to operate the system. More precisely for:
-
Choosing the combustion parameters;
-
Selecting the options used;
-
Show the temperature in the hot air plenum;
-
Selecting heating priority;
-
Selecting language and units displayed;
-
Viewing statistics;
-
Selecting distribution fan speeds;
-
Troubleshooting to detect problems with the appliance.
16.2. SYSTEM CONFIGURATION
Once the installation is complete and before using the unit, the furnace should be configured to activate all applicable
functions depending on options chosen. To do this, it is important to know which options are installed on your furnace.
Summary of Contents for PF01015
Page 10: ...10 ADD ON WOOD ONLY WOOD ELECTRIC WOOD OIL ...
Page 13: ...13 INSTALLATION AND OPERATION INSTRUCTIONS CADDY ADD ON SERIAL INSTALLATION PF01015 ...
Page 16: ...16 Option 3 Option 4 ...
Page 17: ...17 EXAMPLE 1 EXAMPLE 2 ...
Page 63: ...63 20 GENERAL ELECTRICAL DIAGRAM STANDALONE FURNACE ...
Page 64: ...64 21 ELECTRICAL DIAGRAM FOR PARALLEL FURNACE ...
Page 65: ...65 22 ELECTRICAL DIAGRAM FOR ELECTRIC UNIT ...
Page 78: ...78 31 ELECTRICAL DIAGRAM BECKETT OIL UNIT ...
Page 79: ...79 32 ELECTRICAL DIAGRAM RIELLO OIL UNIT ...
Page 81: ...81 33 4 AIR CONDITIONNING DAMPER 33 5 HUMIDIFIER 33 6 HEAT PUMP ...
Page 82: ...82 34 EXPLODED VIEW AND PART LIST ...
Page 83: ...83 ...
Page 84: ...84 ...
Page 85: ...85 ...
Page 86: ...86 ...
Page 87: ...87 ...
Page 88: ...88 ...
Page 89: ...89 ...