Summary of Contents for SBB100

Page 1: ...rnace Save these instructions for reference This furnace must be installed and serviced by a qualified installer and where required by law a licenced technician SUMMERAIRE MFG PETERBOROUGH ONTARIO FOR SERVICE CALL NAME ______________________________ ADDRESS _ _________________________ _____________________________________ TELEPHONE ________________________ ...

Page 2: ... the Canadian Standards Association Laboratories and carry their Certificate of approval which is recognized by Insurance Underwriters in Canada WARNING DO NOT USE CHEMICALS OR FLUIDS TO START THE FIRE NEVER FIRE WITH TREATED WOOD OR BURN GARBAGE GASOLINE NAPTHA OR ENGINE OIL DO NOT FILL THE FIREBOX ABOVE THE BOTTOM OF THE SMOKE BAFFLE LOCATED AT THE TOP PORTION OF THE FIREDOOR OPENING DO NOT STOR...

Page 3: ...N OPERATION This unit is not to be connected to or used with an automatic stoker or sawdust burner Solid fuel fires require sufficient supply of air for combustion Combustion air is required above the fire bed Keep the furnace smoke pipes and chimney clean This will increase efficiency and reduce the risk of excess soot and creosote fires This furnace smoke pipes and chimney should be should be in...

Page 4: ...perly heat your home the air circulation blower fan will begin to come on more frequently In a few days you will establish the basic recharging period for your specific application It is better to build small intense fires than building large smoldering fires as they reduce creosote build up WHEN BURNING WOOD DO NOT FILL THE FIREBOX ABOVE THE BOTTOM OFTHE SMOKE BAFFLE LOCATEDAT THE TOPPORTION OF T...

Page 5: ...mper motor chain an open link is provided in the chain for this purpose Fig 1 Reduce the draft by fully opening the barometric damper Excess heat can damage the safety controls Your complete furnace chimney and controls should be checked by a qualified technician prior to restarting the unit WOOD SECTION OPERATION DURING POWER FAILURE Remove blower compartment door and air filter If necessary inse...

Page 6: ...E COMBINATION FURNACE WITH THE WOOD CHARGING DOOR OPEN CLEANOUTS It is very important to clean the heat exchanger at least on an annual basis One cleanout cover is located on the front of the furnace above the firebox charging door To access this cleanout remove the painted stand off cover Remove cleanout cover by removing the nuts and carefully remove the cleanout cover gasket Use a wire brush to...

Page 7: ...highest allowable limit 230º F or 110º C the damper motor will close the damper door and the oil burner will not start the blower will continue to operate When the temperature returns to normal levels the normal cycle will start OIL SECTION OPERATING INSTRUCTIONS Use No 2 furnace oil ONLY Do not use gasoline crankcase oil or any oil containing gasoline Do not attempt to start the burner if excess ...

Page 8: ...he desired temperature TO TURN THE BURNER OFF Turn the main oil burner switch to OFF Set the thermostat as far below room temperature as possible IF BURNER IS TO BE SHUT OFF FOR AN EXTENDED PERIOD Turn main oil burner switch to OFF Close all oil supply valves The heating system should be checked and cleaned if necessary RESTARTING BURNER AFTER EXTENDED SHUT DOWN The complete oil burner should be c...

Page 9: ... a qualified service technician OIL BURNER SERVICE The oil burner and furnace should be thoroughly serviced annually by a qualified service technician and where required by law a licensed technician AIR FILTER The air filter should be replaced at least every 3 months more often if unit is located in a dusty location The replacement air filter shall be C S A certified DO NOT USE PLEATED TYPE AIR FI...

Page 10: ...point below the factory set temperature The other safety control with a RED button and located beside the above control is a secondary safety limit control This control is a safety override control and acts as a back up control in the unlikely event that the above noted Fan Limit control fails This factory set Limit Temperature of this control is set slightly higher than the limit portion of the F...

Page 11: ...od Govern your wood load with the heat output required Spring and fall require frequent small charges A small intense fire produces less creosote Short flue pipe runs help to keep the gases above the dew point An interior chimney holds and retains heat longer resulting in less condensation than an exterior chimney A good draft produces a hotter fire and exhausts the flue gases outside more rapidly...

Page 12: ...is done to the house there will be damage to the chimney caused by extreme heat Not even the best chimneys are designed to withstand repeated chimney fires FACTORY BUILT CHIMNEY MUST BE LABELED THAT IT COMPLIES WITH UNDERWRITERS LABORATORIES CANADA ULC 629 M Figure 1 ...

Page 13: ...and Local Laws and Codes or ordinances applying to installation of wood or combination wood oil warm air furnaces and failure is not caused by abuse or failure to observe proper operating instructions and cleaning suggestions accompanying the furnace furnace has been fired with the proper type of fuel and maintained in accordance with our instructions furnace has not been fired at an output in exc...

Page 14: ...aned including all areas of the secondary heat exchanger where creosote residue may accumulate and attract moisture from damp basement areas Remember the warranty of this specified it covers the materials and workmanship of the unit It does not cover damage resulting from improper firing practices or maintenance procedures Please follow our instructions and keep your unit operating at peak efficie...

Page 15: ...15 F SBB100 USMAN EN REV3 Summeraire Mfg 2040 Fisher Drive Peterborough Ontario Canada K9J 6X6 ...