11.7. SERVOMOTOR INSTALLATION
See Section 14.5 - SERVOMOTOR INSTALLATION AND CONNECTION
11.8. THERMOSTAT INSTALLATION
See Section 15 - THERMOSTAT INSTALLATION
11.9. OPERATING INSTRUCTIONS
Operate the existing furnace periodically to ensure that it will operate satisfactorily when needed.
On the wood furnace, the thermostat controls the air inlet damper. When the thermostat calls for heat, the damper
opens and the combustion is stirred up. When the furnace gets hot enough, the RTD probe activates the blower motor
at the speed selected for wood heating.
When there is no call for heat, the air inlet damper must be completely closed and the chain must be affixed to the
damper motor at the “8 o’clock” position.